Site requirements

INTRODUCTION

The Rayburn is a floor standing cooker, fired by a gas
burner. It is suitable for vertical flue outlet only.

IMPORTANT

The burner fitted to this appliance has been designed
and constructed exclusively for use with the Rayburn
400 Series Cooker and MUST not be used on any
other appliances or any other uses.

REGULATIONS

In the interests of safety all gas appliances should be
installed by competent persons in accordance with the
regulations in force.
GAS SUPPLY
Installation Pipes
Pipework from the meter to the appliance must be of
adequate size. It is recommended that a minimum of ø22
mm copper tubing is used to within 1m of the appliance.
A reduction to ø15mm is permissible over the last metre
of the appliance. Do not use pipes of a smaller size than
the appliance gas connection. To avoid undue stress on
pipework and burner, adequate support should be used
when connecting and disconnecting union. The complete
installation must be tested for soundness and purged in
accordance with the regulations in force.
FLUE SAFETY DEVICE
For safety purposes a flue safety device is fitted. This will
only operate in adverse flue conditions. If the switch has
operated, it should be pushed in, to reset. If this problem
persists it is necessary to determine and rectify the cause.
If it is found necessary to reset more than once this may
indicate a flue blockage.
FIG. 1A
The appliance is floor mounted and must be installed on
a solid floor or base of non-combustible material which is
capable of supporting the total weight.
The location chosen for the appliance must permit the
installation and the provision of a satisfactory flue and an
adequate air supply. The location must also provide
adequate space for servicing and for air circulation around
the appliance. See "Installation of the Appliance".
The space in which the appliance is to be fitted must have
the following minimum dimensions.
Between wall or unit and LH side of appliance - 10mm
top plate
Between wall or unit and RH side of appliance - 10mm
top plate
SHOULD THE WALL PROJECT BEYOND THE FRONT
OF THE APPLIANCE, IT MUST BE INCREASED TO
50mm (SEE FIG. 1A). To allow door to open enough to
change oven and shelf position.
Above the raised insulating cover handle - 60mm
In addition, adequate clearance must be available at the
front of the appliance to enable it to be operated and
serviced. Flue pipes and fittings must not be closer than
25mm to combustible materials and where passing
through a combustible partition such as ceiling or roof,
must be enclosed in a non-combustible sleeve providing
an air space of at least 25mm.
Spaces around flue pipes passing through walls or floors
should be sealed against the passage of smoke and
flame.
Where the cooker is to stand in a recess or against a wall
which is to be tiled, in no circumstances should the
tiles overlap the cooker top plate.
10mm
WALL PROJECTING BEYOND THE
FRONT OF THE APPLIANCE
5

LOCATION

50mm