Once the appliance has been switched on, set the cock knob on the minimum position.
Remove the cock knob that will reveal a small hole on the panel of the appliance.
Turn the minimum adjustment screw on the cock with a screwdriver through the hole on the panel.
Measure the minimum output pressure directly at the output pressure connection on the injector tube (see figure
"Measuring gas pressure")
Set the output pressure of the gas cock according to the figures stated in table 4 - Minimum output setting).
After setting, seal the adjustment screw!
After each conversion, it is necessary to check tightness and operation!
Warning! :
To ensure correct and safe operation, the appliance must be inspected and serviced at least once a year only. Maintenance includes also to
control the components and tear of pipes, feeding pipes etc..
It is advisable to replace worn components during maintenance operations to avoid the need for other maintenance calls and unexpected
failures.
It is also advisable to apply for a maintenance contract with the customer.
Only technically qualified service centres can perform the operations described below!
Before resetting the safety thermostat, it is always necessary to eliminate the problem causing its activation (only for
models with indirect heating)!
The content of the vat does not heat up:
the safety thermostat has been activated.
The pilot burner is on but the main burners do not light up:
loss of pressure in gas supply;
clogged injectors on main burners.
The pilot burner does not light up:
clogged injectors on pilot burner;
faulty ignition plug;
check the cable of the ignition plug.
The pilot burner does not remain lighted:
faulty thermocouple;
partially clogged injector on pilot burner;
faulty cock magnet.
Safety thermostat
The safety thermostat can be reached by removing the lower front panel once the two side screws have been unloosed.
Main burners
Remove the lower front panel.
Pilot burner
Remove the lower front panel. The pilot burner is in the front of the combustion chamber.
Ignition plug and thermocouple
Remove the lower front panel.
This manual contains all the instructions required for a proper and safe use of our appliances.
Keep the manual in a safe place for future consultation!
This appliance is for catering use, hence they must be used only by trained kitchen staff.
The appliance must always be kept under control during use.
The manufacturer shall not be held responsible for injuries or damage due to the non-compliance with safety rules or an
improper use of the appliance by the operator.
MINIMUM OUTPUT ADJUSTMENT

MAINTENANCE OF THE APPLIANCE

All maintenance operations shall only be performed by a technically qualified service centre!

POSSIBLE FAILURES AND THEIR ELIMINATION

PROBLEM AND POSSIBLE CAUSE
ACCESS TO COMPONENTS AND OPERATION
WARNINGS AND HINTS FOR USER