2
part
nd
For the conversion to another type of gas, e.g.
from natural gas to LPG, the nozzles of the main burner
and the by-pass have to be changed.
All the nozzles necessary for the different types of
gas are marked and placed inside a bag together with
• Remove the control panel by unscrewing the fixing
screws. Unscrew the nozzle with the suitable
• Pull the knob out to access the by-pass.(see fig.1)
The by-pass has to be changed when the unit is converted
from G 30 to G 20 or vice versa (see nozzle table).
The primary air is to be regulated by unscrewing
the fixing screws of the bush and positioning the bush
according to the indications in the "Technical Data"
3
part
rd
An annual check is recommended of all the compo-
nents installed for combustion, ignition and unit safety.
Only qualified personnel may replace faulty parts.
Prior to commencing any kind of work disconnect
the unit from the gas distribution network.
After having removed the control panel, all the
4
th
part
The unit must never be left unattended when it is
being used!
When the unit is on its sides get very hot so please
take great care!
This unit is for professional use, hence, only quali-
fied personnel can use it!
Installation as well as any conversion or adapta-
Burner
Minimum by-pass
Primary air flux adjustment
Parts replacement
Safety precautions
GB
4
Conversion or adaptation
the unit. They are marked according to the nozzle table.
Note: Subsequent to each adaptation or conver-
sion the unit must undergo a functions test and the
supplementary plate updated according to the con-
version or adaptation made.
spanner and replace it with the correct nozzle (see
fig.5).
Attention: In the case of G 30 and G 20, screw
the minimum by-pass right down.
table (Distance "H" of the primary air). Tighten the
fixing screw (See fig. 5).

Maintenance

functional parts of the appliance are easily accessibles
Spare parts must be requested only from the
manufacturer.
Operating instructions
tion to a different type of gas must be carried out in
accordance with current laws and only by qualified
and authorized personnel.
The unit must be checked at least once a year by
qualified personnel. For this purpose we recommend
the stipulation of a maintenance contract.
The appliance has been designed to grill meat.