Gas vehicles
Safety valves
WARNING!
The solenoid valves are only open when the engine is running.
Each tank is fitted with 2 overpressure valves in the rear section. These are
triggered at 16 bar and 24 bar. The safety valves are directed at an inwards
angle and a rearwards angle under the truck.
There is no manual shut-off valve on the gas panel, but there is a manual tap on
each tank. There is a pipe break valve which restricts the flow from the tank in
the event of major leakage from a line. If the pressure exceeds 12 bar on the
low pressure side, a safety valve in the pressure regulator is also opened.
Shut-off cock.
00:01-08 Issue: 8 en-GB
© Scania CV AB
31 (103)