Wiring Diagrams; Wiring Diagram; Switch And Solenoid Wires; Wire From Battery To Motor - Waterous VPE Operation & Maintenance Manual

Table of Contents

Advertisement

Table 1. Switch and Solenoid Wires
Amps
20 or less
3
20 Ga.
4
20
5
20
No.
Description
1
Normally Open Push Button Switch
2
Motor Solenoid
3
Priming Pump Motor
4
Priming Valve Solenoid
5
Dual Batteries
6
Selector Switch
7
Manual−Electric Priming Valve
Figure 12. Wiring Diagram − Models VPE, VPES, VPO, VPOS, HHE and HHEB Priming Pumps
On 24V primers, there is an extra #10 stud on the solenoid. Make sure it is wired to the 5/16 ground stud on the motor frame. The 5/16 ground stud, on both 12V and 24V models,
should be connected to the truck chassis.
F−1031, Section 2312
Length of Wire, Feet
30
40
50
20
20
18
20
18
16
18
16
16
Table 2. Wire from Battery to Motor
Amps
100
16
100
4 Ga.
14
125
12
150
175
200
225
250
270
300
350
Rev: 02/27/06
Length of Wire, Feet (at .2 Volt Drop)
10
20
30
1/0
3/0
2
2/0
4/0
1
3/0
2@2/0
1
3/0
2@2/0
1/0
4/0
2@3/0
1/0
4/0
2@3/0
2/0
2@2/0
2@4/0
2/0
2@2/0
2@4/0
3/0
2@3/0
2@4/0
4/0
2@4/0
40
50
4/0
2@2/0
2@2/0
2@3/0
2@3/0
2@4/0
2@3/0
2@4/0
2@4/0
2@4/0
IL2124
Page 10 of 10

Advertisement

Table of Contents
loading

This manual is also suitable for:

VpesVpoVpos

Table of Contents