3.4 Half Concealed Installation
Only items peculiar to this installation method are given here. See 3.3 Exposed Installation for additional
instructions.
3.4.1 Wall hole
·
Drill a
wall
hole of the size shown in the illustration on the right.
3.4.2 Installation of supplemental plate for attaching main unit
·The rear of the unit can be fixed with screws at the points shown in the illustration as below. Be sure
to install the supplemental plate in accordance with the depth of the inner wall.
Fixing point
on the back
150
250
Supplemental plate
(Field supply)
CAUTION
·
The supplemental plate for installing the main unit must be used or there will be a gap between the
unit and the wall.
3.4.3 Refrigerant piping
·See
3.3.1 Refrigerant piping
Open size
Floor
644
opening
hole
under
3.3 Exposed Unit Installation
Installation and Maintenance
675 685
~
mm
Opening hole
Screw hole
150
230
,
22
73
.
(Unit:mm)
Supplemental plate
(Field supply)
250
200