Hisense AVH-09UXCSAA Operation Installation Maintenance Manual

Hisense AVH-09UXCSAA Operation Installation Maintenance Manual

Inverter-driven multi-split air- conditioner (heat pump)

Advertisement

Quick Links

AVH-09UXCSAA
Floor-
AVH-14UXCSAA
Concealed
Type
AVH-18UXCSBA
AVH-24UXCSBA
UX
UX
UX
UX
P00426Q
ORIGINAL INSTRUCTIONS

Advertisement

loading
Need help?

Need help?

Do you have a question about the AVH-09UXCSAA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hisense AVH-09UXCSAA

  • Page 1 AVH-09UXCSAA Floor- AVH-14UXCSAA Concealed Type AVH-18UXCSBA AVH-24UXCSBA P00426Q ORIGINAL INSTRUCTIONS...
  • Page 3: Important Notice

    To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Hisense Hisense...
  • Page 4 Section2 Installation & Maintenance Manual...
  • Page 5 The appliance is not to be used by children or person with reduced physical, sensory or mental capabilities,or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised that they do not play with the appliance.
  • Page 7: Before Operation

    4. Before Operation Supply electrical power to the system for approximately 12 hours before start-up after long shutdown. Do not start the system immediately after   power supply, it may cause a compressor failure, because the compressor is not heated well. Make sure that the outdoor unit is not covered with snow or ice.
  • Page 8: Troubleshooting

    7. Troubleshooting...
  • Page 9 R410A...
  • Page 11 Ceiling Outlet At least 250 At least 250 Wall At least 800 At least 50 (Maintenance space) Size 09~14 18~24 Fig.4.2 Suspension Bolts...
  • Page 12 4.3.2 Hanging the IndoorUnit 4.3.3 Connecting Supply Duct The supply duct should be inserted onto the root of Prevent the subversion of the machine. The method for ground installation is shown below. the unit outlet. Thermal insulation should be done Fix the unit with bolt in the specified location as and the junction with the unit should be sealed shown in Fig.4.3.
  • Page 13 202 168 72 109 58 50 113 33 Gas pipe Liquid pipe Water tray 09~14 Flaring Dimension Perform the flaring work as shown below. ΦD Φa R410A R407C 6.35 9.1 9.0 13.0 9.53 13.2 12.7 16.2 16.6 15.88 19.4 19.7 ( * )...
  • Page 16 220-240V~ 50Hz 09~24...
  • Page 17 Use an ELB (Electric Leakage Breaker).If not Use an ELB (Electric Leakage Breaker).If not used ,it will cause an electric shock or a fire. used ,it will cause an electric shock or a fire. Run through the cables using conduit tube, Run through the cables using conduit tube, and Completely seal the end of conduit tube and Completely seal the end of conduit tube...
  • Page 18 Ex.) Set at No.5 Cycle Set by inserting Setting DSW5 Slotted screwdriver Position into the groove Set All Pins OFF Before shipment. DSW5 and RSW2 are set to "0". RSW2 Max.64 cycles are available to set when all the equipment to be connected are corresponding to Hi-NET.
  • Page 20 Hisense Corporation Add: 17,Donghai Xi Road,Qingdao 266071,China P00426Q 2012.12...