Special remarks

● 3 minutes protection after compressor stop
To protect compressor, it will be to be continue off for at least 3 minutes once it has stopped.
● 5 minutes protection
Compressor must run at least for 5 minutes once it starts running. In this 5 minutes, compressor will not stop
even if the room temperature reaches the set point unless you use remote control switch to turn off the unit
(all indoor unit can be turned off by user).
● Cooling operation
The fan of the indoor unit will never stop running in cooling operation. It remains running even if the compressor
stops working.
● Heating operation
Heating capacity depends on external factors as outdoor unit temperature. Heating capacity might decrease
if outdoor ambient temperature is too low.
● Anti-freezing function during cooling
When the temperature of the air from the indoor outlet is too low, the unit will run for some time under the fan
mode, to avoid frost or ice forming in the indoor heat exchanger.
● Cold air prevention
In several minutes after the heating mode is started, the fan of the indoor unit will not run until the heat
exchanger of the indoor unit reaches a certain temperature to prevent cold draft.
● Defrosting
When the outdoor temperature is too low, frost or ice may form on the outdoor heat exchanger, reducing
heating performance. When this happens, a defrosting system of the air conditioner will operate. At the same
time the fan in the indoor unit stops (or runs at a very low speed in some cases), to prevent cold draft. After
defrosting is over, the heating operation and fan speed restarts.
● Blowing out the residual heating air
When air conditioner is stopped during normal operation, the fan motor will run with low speed
for a while to blow out the residual heating air.
● Auto restart from Power Break
When the power supply is recovered after power break, all presets are still effective and the air
conditioner will run according to the previous setting.
● Mode Interfere (Only for multi-split)
For the reason that all indoor units use one outdoor unit, outdoor unit can only run with same
mode (cooling or heating), so, when the mode you set is different from the mode that outdoor is running with,
mode interfere occurs. Following shows the mode interfere scene.
cooling
dry
cooling
dry
heating
×
fan
Outdoor unit always run with the mode of first indoor unit that turned on. when the setting mode of following
indoor unit is interfered with it, 3 beeps would be heard, and the indoor unit interfered with the normal running
units would turn off automatically

Troubleshooting

CAUTION
If drain water overflows from indoor unit, stop the operation and contact your dealer.
If you smell or see white smoke coming from the unit, turn OFF the main power supply and contact
your dealer.
1. If Trouble Still Remains ...
If the trouble still remains even after checking the following, contact your deale r and inform them of the
following items.
(1) Unit Model Name
(2) Content of Trouble
2. No Operation
Check whether the SET TEMP is set at the correct temperature.
heating
fan
×
×
×
×
×
√ --- normal
× --- mode interfere
10