Physical Specifications; Regulatory Information; Installation - WINDY NATION TrakMax 30L User Manual

Mppt solar charge controller
Table of Contents

Advertisement

TrakMax 30L User Manual
Revision 1.0
Max Input Current
Max Battery Charging Current
Load Current
Max PV Open Circuit Array Voltage
Efficiency
Typical Idle Consumption
Bulk Charge
Floating Charge
Over-voltage Indication
Over-voltage Recovery
Under-voltage Indication
Under-voltage Recovery
Temperature Compensation
Load Control
Low Voltage Reconnect
Low Voltage Disconnect
Altitude
Enclosure Protection Class
Battery Temperature Sensor (BTS)
Terminal Size (fine/single wire)
NOTE: The optional battery temperature sensor automatically adjusts the charging process of the controller
according to the type of battery selected by the user. With the battery temperature sensor installed, the controller
will increase or decrease the battery charging voltage depending on the temperature of the battery to optimize the
charge to the battery and to maintain battery performance.
2.2.2

Physical Specifications

Parameter
Dimension (H x W x D)
Unit Weight
Mounting
Cooling
Operating Temperature
Storage Temperature
Operating Humidity
Non-Operating Humidity
2.2.3

Regulatory Information

The TrakMax has safety approvals as follows:
CE
IEC 62109
FCC Requirements:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

3 INSTALLATION

 Insure all terminating connections are clean and tight to prevent arcing and overheating.
 Do not connect to a PV array capable of producing greater than 30 amps of short circuit current @ 25°C.
 Do not connect to a PV array with an open circuit voltage (VOC) greater than 150VDC.
Page 6 of 29
10, 20, or 30 Amp
97% @ full current
< 160mA / 80mA / 40mA
14.4V(default)
13.5V / 27V / 54V (default)
15.0 / 30.0 / 60.0 VDC
14.8 / 29.6 / 59.2 VDC
8.5 / 17.0 / 34.0 VDC
9.0 / 18.0 / 36.0 VDC
0 - 10mV/
ON / OFF
12.0 / 24.0 / 48.0 VDC
10.5 / 21.0 / 42.0 VDC
Operating 6,560ft (2000m)
Optional sensor increases charging precision
Maximum 6 AWG
8.2" (210mm) x 6.7" (171mm) x 3.8" (98mm)
4.4 lb. (2Kg)
Vertical wall mount - indoor only
Natural cooling
o
14
F to 122
de-rating >104
o
-25
20 to 80% relative humidity (non-condensing)
Greater than 95% relative humidity
o
38.7
C max wet bulb temperature with no damage
windynation
30 Amp
10 Amp
150VDC
o
C (settable)
IP20
Value
o
o
o
F (-10
C to 50
C)
o
o
F (40
C)
o
C to 60
C
05/06/2015

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chc-trmx-30

Table of Contents