Lcd Interface Cycle; Interface Definitions; Pv / Solar Input Interface (Main); Battery Interface - Charge Limit Setting - WINDY NATION TrakMax 30L User Manual

Mppt solar charge controller
Table of Contents

Advertisement

TrakMax 30L User Manual
Revision 1.0
4.6 LCD I
NTERFACE
4.7 I
D
NTERFACE
The TrakMax has six different graphical interfaces. Each interface contains different information. There are five
interfaces with the symbol
4.7.1

PV / Solar Input Interface (Main)

This is the MAIN Interface and the displayed number is the present Solar Panel voltage (displayed in Volts) and
the solar panel current (displayed in Amps).
4.7.2
Battery Interface – Charge Limit Setting
The Battery Interface displays the current Battery voltage and current. The TrakMax supports a maximum
charging current of 30A, but this can be modified to limit the charge to 10A, 20A, or 30A. Default Setting: 30A.
From the Battery Interface, press the ENTER key and hold for 3 seconds to enter setup mode. Once in setup
mode
will blink and "LIMIT" will be displayed. Press the UP or DOWN keys to adjust to the desired value and
press ENTER to save and return to main page.
NOTE: If you do not want to save the setting, press the BACK key to return to main page and original set value.
Page 19 of 29
ERROR Symbol.
When present check the TrakMax controller and refer to Section
5 (Error Conditions) and 6 (Troubleshooting)
PARAMETER SET Symbol
When present in a particular interface, there is a user
configurable parameter available. Press ENTER and the
C
YCLE
EFINITIONS
, these interfaces contain configurable parameters.
PV Indicator
windynation
Solar Panel Voltage
Solar Panel Current
05/06/2015