Insert Wire/Cable Here
a) Load: Maximum 10A DC Load
• Connect a cable from the TrakMax terminal marked load negative (–) to the negative terminal of your
DC load and tighten the screw.
• Connect a cable from the TrakMax terminal marked load positive (+) to the positive terminal of your DC
load and tighten the screw.
b) Battery: 30A Rated Charge Current
• Connect a cable from the TrakMax terminal marked battery negative (–) to the negative (–) battery
terminal and tighten the screw.
• Connect a cable from the TrakMax terminal marked battery positive (+) on the Solar charge controller to
the positive (+) battery terminal and tighten the screw.
IMPORTANT: A properly sized fuse must be placed in the positive wire connecting the charge controller to
the battery.
c) PV: Photovoltaic System
• Connect the PV array's positive (+) output to the terminal marked PV positive (+) on the TrakMax and
tighten the screw.
• Connect the PV array's negative (–) output to the terminal marked PV negative (–) on the TrakMax and
tighten the screw.
IMPORTANT: A properly sized fuse must be placed in the positive wire connecting the solar panels to the
charge controller.
4) Double Check All Connections to ensure they are secure.
5) Replace the Wiring Cover removed in step 1 and secure with the four screws.
6) Tighten the cable clamps (if applicable)