Environment Temperature Sensor (Env) - WINDY NATION TrakMax 30L User Manual

Mppt solar charge controller
Table of Contents

Advertisement

TrakMax 30L User Manual
Revision 1.0
When the BTS detects a temperature of 50
temperature is within a safe operating zone.
3.8.2.1
1) The BTS cable is 5m in length and has two plain wires on one end and lug on the other end.
2) Strip approximately ¼" from each wire end, insert the bare wire into the two left terminals on the
temperature sensor connector, and tighten the terminal screws on top of the connector as shown below.
3) Plug the provided Temperature Sensor Connector into the socket located on the controller labeled
"Temp Sensor" and tighten the two captive screws to secure the connector in place as shown below.
4) Secure the BTS on the side of the battery below the electrolyte level as shown below. It is best to place
the sensor between batteries and place the batteries in an insulated box to reduce the influence of the
ambient temperature outside the battery enclosure.
3.8.3

Environment Temperature Sensor (ENV)

The Environment Sensor is used to automatically compensate the charging voltage based on the Battery
Temperature Compensation setting; See Sec 4.7.5.
3.8.3.1
1) The ENV cable is 5M in length and has two plain wires on one end and a thermocouple sensor on the
other end.
2) Strip approx. ¼" from each wire end, insert the bare wire into the two right terminals on the temperature
sensor connector, and tighten the terminal screws on top of the connector as shown below.
3) Plug the provided Temperature Sensor Connector into the socket located on the controller labeled
"Temp Sensor" and tighten the two captive screws to secure the connector in place as shown below.
Page 13 of 29
o
C (122
BTS Installation
ENV Installation
windynation
o
F) the TrakMax will stop the charge current until the
05/06/2015

Advertisement

Table of Contents
loading

Related Products for WINDY NATION TrakMax 30L

This manual is also suitable for:

Chc-trmx-30

Table of Contents