  • Page 1 20L High-Capacity Compressor Dehumidifier Model: MOR-DHE-D068 GTIN/EAN: 5060556812125 INSTRUCTION MANUAL Page 1...
  • Page 2: Table Of Contents

    Thank you for choosing the Morris dehumidifier. Be sure to read this manual carefully before using it. Any questions, please contact Morris’s customer care team. Table of contents Before you begin For you safety Installation Operation Maintenance Troubleshooting Product specification...
  • Page 3: Before You Begin

    1. BEFORE YOU BEGIN Please read the operating instructions carefully before using your dehumidifier for the first time. 1.1 PRODUCT DESCRIPTION The dehumidifier is used to remove excess moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity. The environmentally friendly R290 is used as the refrigerant.
  • Page 4 1.2 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance safely and understand the hazards involved.
  • Page 5: For You Safety

    2. FOR YOUR SAFETY Your safety is the most important thing we are concerned about! Please read this manual carefully and fully understand it before operating your dehumidifier. 2.1 OPERATIONAL PRECAUTIONS WARNING- to reduce the risk of fire, electric shock or injury to persons or property: •...
  • Page 6 Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. If you don't understand something or need help, please contact the Morris customer care team. Page 6...
  • Page 7 2.2 SAFETY PRECAUTIONS ON SERVICING Please follow these warnings when to undertake the following when servicing a dehumidifier with R290. 2.2.1 Checks to the area. Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized.
  • Page 8 2.2.6 No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
  • Page 9 2.2.9 Checks to electrical devices Repair and maintenance of electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise the safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately, but it is necessary to continue operation, an adequate temporary solution shall be used.
  • Page 10 3. PRODUCT OVERVIEW Air Outlet Control Panel Handle Air Filter Continuous Back Drainage Shell Front Shell 3 Colors Outlet Indicator Light Water Tank Castors Page 10...
  • Page 11: Installation

    4. INSTALLATION 4.1 OPERATIONAL PRECAUTIONS Place the unit on a firm, level surface in an area with at least 30 cm of free space around it to allow for proper air circulation. Never install the unit where it could be subject to: •...
  • Page 12 4.2 OPERATING THE DEVICE SAFELY • Check the device after unpacking for any damages or scratches on it. • Operate this unit at an ambient temperature from 5° C to 35° C. • Do not use it outdoors. This dehumidifier is intended for indoor residential applications only. •...
  • Page 13: Operation

    5. OPERATION 5.1 3-COLOURS INDICATOR LIGHT Ambient humidity <= 45%, the indicator light will show Blue. 45% < ambient humidity < 65%, the indicator light will show Green. Ambient humidity <= 65%, the indicator light will show Red. 5.2 CONTROL PANEL 5.3 SETTINGS Stand By Button Press the STAND-BY button to turn on the machine, the running indicator lights up and the default fan...
  • Page 14 Mode Button Press the mode button to switch between Auto and Continuous dehumidifying modes. Auto mode - continuously dehumidify the mode cycle, press once to switch the mode from one to another, and the corresponding indicator will light up. - Auto mode: In this mode, you can select your required humidity level from the dashboard. Once the humidity level is set and the room humidity >= your set humidity +3%, the fan will immediately start working followed by the compressor which will start up after a 3-second delay.
  • Page 15 Fan Speed Button Press this button to switch the fan speed between the high and low fan speed cycle, and the corresponding indicator light will be on. The fan speed can be adjusted only in Auto mode. Adjust Button Press this button to set the humidity and timer; To adjust the humidity, press once to add a 5% humidity value, the humidity will adjust in the following order: 30% - 35% - 40% - 45% - 50% - 55% - 60% - 65% - 70% - 75% - 80% - 30% cycle To adjust the timer, press one time to add a 1-hour timing value, the timing follows the order as below:...
  • Page 16 1) When the tank is full, The machine will buzz 5 times, and the “Water Tank Full” indicator light will light up. 2) Press the POWER button to turn off the unit. 3) Pull on the water tank and simply slide out of the body of the dehumidifier. 4) Empty the water into an area with a drain or outside.
  • Page 17 Warning • Do not discard the magnets and plastic rivets in the tank. Otherwise, the dehumidifier cannot be started, or the machine will not automatically stop working when the water tank is full, and the condensed water overflow will damage the floor of the room. •...
  • Page 18: Maintenance

    6. MAINTENANCE Note: Before cleaning and maintaining the machine, please be sure to turn off the machine and unplug the power to avoid electric shock. CLEANING THE AIR FILTER (every two weeks) Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
  • Page 19: Troubleshooting

    7. TROUBLESHOOTING SYMPTOM INSPECTION SOLUTION Check the power Insert the power cord securely into the wall connection in secure. outlet. The unit is not Check if the water level Empty the water tank and reinstall it operating. indicator lights up. correctly.
  • Page 20 SYMPTOM INSPECTION SOLUTION Check if the unit is securely Place the unit on horizontal and firm ground. positioned. Check if any loose, Excessive Noise Secure and tighten the parts. vibrating parts. The noise sounds like water Noise comes from flowing refrigerant. This is flowing.
  • Page 21: Product Specification

    8. PRODUCT SPECIFICATION Dehumidifying Technology Compressor / Refrigerative Dehumidifier Large Water Tank Capacity With Full 4.5L Indicator Light  and Auto Shut-off Max Daily Extraction Recommended for Room Size 322 sq. ft. or 30m² (height=2.6m) Auto-on and Auto-off Timer 1-24 Hr Energy Consumption 0.33 kW/h Working Temperature 5 - 35°C...