Summary of Contents for Morris MOR-12LDHE-WIFI

  • Page 1 INSTRUCTION MANUAL MOR-12LDHE-WIFI Please keep this manual for further reference! Thank you for selecting our dehumidifier. Be sure to read this manual carefully before using it. Any questions, please contact enquiries@ledfirstchoice.co.uk for help.
  • Page 2: Table Of Contents

    CONTENT 1. BEFORE YOU BEGIN..........03 2. FOR YOUR SAFETY............05 3. PRODUCT OVERVIEW..........10 4. INSTALLATION............12 5. OPERATION..............14 6. MAINTENANCE............19 7. TROUBLESHOOTING..........20 8. DECOMMISSIONING..........21...
  • Page 3: Before You Begin

    1. BEFORE YOU BEGIN Please read the operating instructions carefully before using your dehumidifier for the first time. 1.1 PRODUCT DESCRIPTION The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity.
  • Page 4: For Your Safety

    shops, in light industry and on farms, or for commercial use by lay persons. This appliance can be used by children aged from 8 years and above ● and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5 Please read this manual carefully and fully understand before operating your dehumidifier. OPERATIONALPRECAUTIONS WARNING- to reduce the risk of fire, electric shock or injury to persons or property: If the supply cord is damaged, it must be replaced by the manufacturer, ●...
  • Page 6 The appliance shall be stored in a room without continuous operation ● sources (for example: open flames, an operating gas appliance or an operating electric heater). ● The appliance shall be stored to prevent mechanical damage from occurring. Do not piece or burn, even after use. ●...
  • Page 7 2.2.2 Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed. 2.2.3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out.
  • Page 8 maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: – The charge size is in accordance with the room size within which the refrigerant containing parts are installed;...
  • Page 9: Product Overview

    3. PRODUCT OVERVIEW FRONT VIEW Touch Panel Air Outlet 3 Colour Digital Display Front shell Castors ...
  • Page 10 Back Shell Air Filter ConEnuous drainage Visible Water Level Water tank 3.2 FEATURES Powerful moisture removal (up to 12L/day dehumidification) ● Humidity Monitor shows current air humidity ● Auto mode automatically adjusts humidity levels ● ● A 24-hour timer to set the time of operation Effectively removes moisture, dust from the air ●...
  • Page 11: Installation

    Noise ≤36dB(A) Water tank capacity 2.0L Maximum Refrigerant Charge R290/55g Net weight 11kg High Side: 3.2MPa, Maximum Design pressure Low Side:0.7MPa 4 ㎡ (Floor area) Minimum Room size Dimension 255*220*460(mm) Fuse type and rating: T-Typ, AC 250V, 3.15A 4. INSTALLATION 4.1 LOCATION 1.
  • Page 12 WARNING nstall the unit in rooms which exceed 4 m². Do not install the unit in a place where inflammable gas may leak. NOTE The manufacture may provide other suitable example or may provide additional information about the refrigerant odour. 4.2 OPERATING THE DEVICE SAFELY ●...
  • Page 13: Operation

    Do not operate or store the unit in direct sunlight or rain. ● It is normal for air outlet to feel warm to touch after continuous operation ● on hot days. Empty the water tank before moving the device. ● Make sure the Water tank is correctly fitted otherwise the unit will not ●...
  • Page 14 Power In the standby state, press the power button to turn on, the operation indicator lights up and the default fan speed is high, and the default humidity is 50%. In the power-on state, press the power button to turn off, the running indicator light goes off and the compressor stops immediately, and then the fan shut down after 30 seconds delay.
  • Page 15 Press the timer button to set the 0-12 hour timing function. The interval is 1 hour. Each time you press this button, the value increased 1 hours and then the corresponding timing value is displayed on the screen. The setting value is “00”...
  • Page 16 5.3.1 EMPTYING THE WATER TANK The water tank built in unit will fill up and shut the unit down once it is full. It will run again once you empty the water tank and installed properly. When the tank is full, The unit will make a buzzing sound, and the ●...
  • Page 17 Securely and properly connect the drain hose and make sure it is not ● kinked and clear of obstruction. Place the outlet of hose over a drain or bucket and ensure that water ● could freely flow out of the unit. Do not submerge the end of hose into water;...
  • Page 18 6. ADDITIONAL WIFI FUNCTION Information on the App “Smart Life” “Smart Life” app is available for android and iOS. Scan the corresponding QR code to get directly to the download. Information on How to Use the App This appliance allows you to operate the appliance via your home net-work. A prerequisite is a permanent WIFI connection to your router and the free app “Smart Life”.
  • Page 19 Picture2 Picture1 Picture3 Picture4 TROUBLE SHOOTING of WIFI CONNECTION...
  • Page 20: Maintenance

    Network connection failed Solution 1.Check if you select the WIFI named “SmartLife- XXXX”. Network connection timeout 2.Turn off the machine and unplug the power code and plug in after 10 seconds, enter the App to connect again. Long press the “Timer”button or Turn off the machine WIFI indicator off and unplug the power code and plug in after 10 seconds.
  • Page 21: Troubleshooting

    3.Put the filter back. 8.TROUBLE SHOOTING 1. FUNCTIONING TEMP. 5°C ≤ Ambient Temp. ≤ 35°C When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops. When 5°C ≤ Ambient temp. ≤ 16°C, the compressor automatically defrosts at intervals;...
  • Page 22: Decommissioning

    Is the air filter clogged? Clean the air filter as instructed Is the intake duct or discharge Remove the obstruction from the functioning duct obstructed? discharge duct or intake duct. No air intake Is the filter clogged? Wash the filter Is the machine put in the plat Loud noise Put the machine on the plat ground...
  • Page 23 2. DISPOSAL WARNING!!! Releasing refrigerant into atmosphere is strictly forbidden! Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well- being Importer : LED First Choice LTD...