Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MDE24291 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Morris MDE24291

  • Page 2: Table Of Contents

    Contents Safety Instructions Installation Parts Control Panel Quick reference guide Positioning Water Drainage Care and Maintenance Troubleshooting Product Repair This product is using the Environment friendly refrigerant R290.(ODP value is 0,GWP value is 3.3), this refrigerant is tasteless and combustrible, moreover,it can burn and explode under a certain conditions;so please read this user manual carefully before using and maintenance.
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS Important The room area of this product should be more than 4m when it is used, repaired and stored. This product needs to be used and stored where there is no fire source (such as electric heater at work, stove with open fire, etc.) This product refrigerant may be odorless.
  • Page 4 Avoid restarting the dehumidifier unit unless 5 minutes have passed since being turned off. This prevents damage to the compressor. Never use the mains plug as a switch to start and turn off the dehumidifier. Use the provided ON/OFF switch located on the control panel. Always place the unit on a dry and stable surface.
  • Page 5: Installation

    The compressor dehumidifiers are ideal for normal domestic or office environment which are heated during the winter months with temperatures above C. MORRIS dehumidifiers are easy to move around on castors and intelligent 12-15 dehumidifiers which will extract unwanted humidity while saving money due to their humidistat and power saving logic.
  • Page 6: Parts

    PARTS GENRERAL DESCRIPTION Oscillation louver Air outlet Control panel Lamp Wheel Handle Filter Air inlet Continuous drain port Water tank Back cover Power cord...
  • Page 8 HUMIDITY SETTING Press UP / DOWN key to select the desired relative humidity level, default relative humidity is 55%. Relative humidity 35% is selected, the compressor will not stop until water tank full. TIMER (timer function) Press timer to program time. "TIMER" light comes on while timer is TIMER programmed.
  • Page 9: Quick Reference Guide

    QUICK REFERENCE GUIDE POWER Power Key Press to turn the dehumidifier on and off. TIMER Timer: select timer settings key then use keys to adjust the timer (1-24 hrs, start/ stopping timer). In power on mode the set number will represent the number of hours the unit will run for before turning off.
  • Page 10 The dehumidifier is built to be compact and lightweight. The castors on the bottom of the unit make it easy to move from room to room. Your MORRIS dehumidifier is an advanced micro-CPU controlled device able of self- diagnostics. The LCD display may also show the error and protections codes.
  • Page 11: Water Drainage

    Positioning the dehumidifier A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation of air in not restricted around the unit. Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential / small office applications and any commercial or industrial use will invalidate the warranty.
  • Page 12: Care And Maintenance

    NOTES: When you remove the bucket, do not touch sensors or any parts which are situated behind tank. Doing so may damage the product. Be sure to push the tank gently all the way into the unit. Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate.
  • Page 13 outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a soft damp cloth or kitchen towel. Remove the ABS frame and pull out the filters from the frame. Hoover gently the optional carbon once every 2-3 weeks approximately.
  • Page 14: Troubleshooting

    Troubleshooting: Issue Cause Solution Hot or cold Normal Operation When the unit is in dehumidifying mode it absorbs humid air air being from room and freezes it to reduce the humidity. produced During the cold cycle there should be cold air coming out of the unit.
  • Page 15: Product Repair

    PRODUCT REPAIR Warning: The appliance should be stored in a well-ventilated room. The area of the room should be equal to the room area required for maintenance. ——Warning: Appliances should be stored in rooms where there is no continuous burning fire (such as ignited gas appliances) and ignition sources (such as electric heaters at work) -——All operators or refrigeration circuit maintenance personnel should obtain a valid certificate issued by an industry-approved assessment agency to determine their qualification for safe...
  • Page 16 The following inspection items apply to the installation of flammable refrigerant appliances: - The charge should be determined according to the size of the room containing the refrigerant containing components; - Ventilation equipment should operate normally and vents should be free from obstructions; - If an inter-refrigeration refrigeration cycle is used, check the presence of refrigerant in the secondary circuit;...
  • Page 17 F. Leak detection method For systems containing flammable refrigerants, the following methods for detecting leaks are acceptable: Electronic leak detectors can be used for the detection of flammable refrigerants, but the sensitivity may not be sufficient or may require recalibration (the instrument calibration should be performed in a refrigerant-free environment) to ensure that the leak detector does not become a potential The ignition source, and applies to the measured refrigerant, the leak detector should be set to the lowest flammable concentration of the refrigerant (in percent),...
  • Page 18 I. Retired Before proceeding with this procedure, technicians should be fully familiar with the equipment and all its features and recommend the practice of safe recovery of refrigerants. To recycle the recovered refrigerant, analyze the refrigerant and oil samples before performing the work. Before testing, ensure that you have the necessary power supply.
  • Page 19 Herewith, Amiridis-Savvidis S.A. states that this product, complies with the requirements of below directives: EMC-Directive: 14 / 30 / EU Low Voltage Directive: 14/ 35 / EU RoHS Directive: 11 / 65 / EU The detailed declaration of conformity can be found at www.morris.gr...

This manual is also suitable for:

Mde20291

Table of Contents