Tubing Connection; Connection Of Wires - Beko BRAE 090 User Manual

Table of Contents

Advertisement

Available languages

Available languages

7
Installation manual
• Regularly check the reliability of the installation
frame.
Installation support
Fig. 10
7.9

Tubing connection

• Detach the valve cover of outdoor unit.
• Align flaring nut to the thread center, and
screw the nut tightly by hand.
• Screw tightly the flaring nut with torque
spanner until the torque spanner produces
"click" sound.
• It is recommended to use torque spanner to
connect the tubing. If other flexible or fixed
spanner is used, it may damage the horn
mouth due to improper force.
• The bending angle of the tube should not be
too small or the tube may break up, so the
service personnel should use tube bender to
bend the tube.
• Never let water, dust or sand gets into the
pipe.
34 / 46 EN
Thread
Wrench
Fig. 11
Table 2
Tubing size (mm/inch)
Ø 6 (1/4")
Ø 9.52 (3/8")
Ø 12 (1/2")
Ø 15.88 (5/8")
Ø 19.05 (3/4")

7.10 Connection of wires

1. Indoor unit
• Open upward the inlet grid to the greatest
extends.
• Remove the electric cover from the unit.
• Loose the screw at connection lid. (Fig. 12)
• Dismantle the wire pressure plate.
• Connect the power connecting wires
and signal control wire separately to the
corresponding terminals. (In Fig.14, please
choose the same wiring diagram just with the
wiring diagram of unit.)
• Loose off the screw on the earth plate; press
earth wire tightly.
Split Type Air Conditioner / User Manual
Flaring nut
Pipeline
Torque Wrench
Torque (N. m)
15~20
35~40
50~55
60~75
80~95

Advertisement

Table of Contents
loading

Table of Contents