7
Installation manual
Power Connection Of
Indoor And Outdoor Unit
Brown
Blue
Yellow/Green
Red
White (Yellow)
Signal control wire
Warning:
Please connect as the above
A
diagram shown, or it may
cause units malfunction.
Cut off power source before
disassembling connection lid.
Note:
• Earthing screw must use
special screw (stainless
machining screws or copper
screws M4)
• Ensure that all wires are
securely connected, will not
C
loose or separate.
• Ensure that wire connections
are carried out according to
the wiring diagram of the air
conditioner.
• The above figures are only
schematic, and they may
be slightly different from the
actual appliances you select.
Split Type Air Conditioner / User Manual
Power Connection Of
Indoor And Outdoor Unit
Brown
Blue
Yellow/Green
Red
White
Black (Yellow)
Signal control wire
Warning:
Please connect as the above
A
diagram shown, or it may
cause units malfunction.
Cut off power source before
disassembling connection lid.

7.11 Tube strapping

• Strapping with PVC Protective tape must be
careful, do not damage the pipeline and drain
pipe.
• Strapping should start from the lower part of
the outdoor unit to the indoor unit.
• Fix the PVC tape with adhesive tape to
prevent loosing.
• Drainpipe should slightly slide down outwards
to ensure drainage well.
• When the indoor unit is lower than the outdoor
unit, bend the tube to proper extent to prevent
water draining into house.
• Fix the tube bundle with tube clamps on the
wall.
• Allow enough space between discharge pipe
and the ground. Do not put the discharge pipe
in water or ditch.
• Seal the external wall holes with sealing gum
or putty.
Fig.14
37 / 46 EN