HORNER XL6 Prime Data Sheet / Manual

HORNER XL6 Prime Data Sheet / Manual

Hide thumbs Also See for XL6 Prime:

Advertisement

Quick Links

 
Part Numbers
Global Part Number
European Part Number
 
User Manual and Add-Ons
Find the documents via the Documentation Search. 
 
Part #
MAN1032
EXL6 & XL6 Prime User Manual
MAN1142
Rechargeable Battery Manual
HE-BAT019
Rechargeable 3.6V Lithium Battery
HE-XCK
Programming Cables
2 channel Analog Output I/O option kit, 
HE-XDAC
selectable 0-10V, +/-10V, 4-20mA.
4 channel Analog Output I/O option kit, 
HE-XDAC107
selectable 0-10V, +/-10V, 4-20mA.
HE-XKIT
Blank I/O Board
Adapter, RJ45 (8P8C) male to 8-pos-
HE200MJ2TRM
ition terminal strip. 
Ferrite core for filtering out electrical 
HE-FBD001
noise. 
 
 
Backup Battery
The XL6 Prime uses a Renata CR2032 lithium battery to 
run the Real Time Clock. The battery life is 7-10 years.
 
 
 
 
 
XL6 Prime Datasheet - Model 2
12 DC In, 6 Relay Out, 4 - 12-bit Analog In
MAN1327-21-EN_XL6P_Mod2
HE-XPL1E2
HEXP371C112
Description

Table of Contents

 
 
Page 1
1
1
2
2
2
2
2
3
3
3
4
4
4
4
5
5
5
5
5
5
6
6
6
6
6
7
7
7
7
7
8
8
8
8
9
9
9
9
9

Advertisement

Table of Contents
loading

Summary of Contents for HORNER XL6 Prime

  • Page 1: Table Of Contents

    XL6 Prime Datasheet - Model 2 12 DC In, 6 Relay Out, 4 – 12-bit Analog In MAN1327-21-EN_XL6P_Mod2 Table of Contents User Manual and Add-Ons Backup Battery TECHNICAL SPECIFICATIONS General Specifications Control and Logic User Interface Connectivity   CONTROLLER OVERVIEW Part Numbers Overview of OCS Power Wiring Global Part Number HE-XPL1E2...
  • Page 2: Technical Specifications

    TECHNICAL SPECIFICATIONS General Specifications User Interface Typical   P ower   B ack- Display   T ype 5.77”   V GA   T FT   ( 450 nit   t ypical) 415mA @ 10VDC (4.15W) 191mA @ 24VDC (4.58W) light 100% Resolution 640   x    4 80 Power   B acklight   @   Color 16-bit   ( 65,536) 111mA @ 24VDC (2.66W) Screen  ...
  • Page 3: Controller Overview

    CONTROLLER OVERVIEW Overview of OCS Power Wiring NOTE: The Primary Power Range is 10VDC to 30VDC.     Primary Power Port Pins Signal Description Ground Frame Ground Input Power Supply Ground Input Power Supply Voltage     DC Input / Frame     Solid/Stranded Wire: 12-24 awg (2.5-0.2mm)   Strip length: 0.28” (7mm)  1.  Touchscreen   Torque, Terminal Hold-Down Screws: 4.5 – 7 in-lbs   2.  Function Keys (0.50 – 0.78 N-m)  3.  USB 2.0 “A”: Flash Drive  ...
  • Page 4: Model 2 Specifications

    Wiring: Model 2   MODEL 2 SPECIFICATIONS   Digital DC Input Analog Inputs, Medium Resolution 12   i ncluding   4    c onfigurable   H SC   Number   o f   C hannels Inputs   p er   M odule inputs Input   R anges 0-10VDC,   0 -20mA, 4-20mA Commons  ...
  • Page 5: Wiring: Inputs And Outputs

    NOTE: When using JP2 (A1-A4), each channel can be inde- Digital inputs may be wired in either a Positive Logic or Neg- pendently configured. ative Logic fashion as shown. The setting in the Cscape    Hardware Configuration for the Digital Inputs must match  Back Panel Torque Ratings the wiring used in order for the correct input states to be  registered. No jumper settings are required for XLEe/XLTe.  XLE/XLT: 3.0 - 4.0 in-lbs (0.34 - 0.45 N-m) When used as a normal input and not for high speed func- XL4/XL4 Prime: 3.0 - 4.0 in-lbs (0.34 - 0.45 N-m) tions, the state of the input is reflected in registers %I1 –  EXL6/XL6 Prime: 3.0 - 4.0 in-lbs (0.34 - 0.45 N-m) %I12. EXLW/ XLW Prime: 3.0 - 3.5 in-lbs (0.34 - 0.40 N-m)   XL7/XL7 Prime: 3.0 - 3.5 in-lbs (0.34 - 0.40 N-m)     EXL10/XL10 Prime:   3 .0 - 3.5 in-lbs (0.34 - 0.40 N-m)             Page 5...
  • Page 6: J1 Wiring - Digital In / Analog In

    Wiring: Model 2 J1 Wiring - Digital In / Analog In Wiring Details Solid/Stranded Wire:   1 2-24 awg (2.5-0.2mm2). Strip Length:   0 .28” (7mm). Torque, Terminal Hold-Down Screws:   4 .5 – 7 in-lbs  (0.50 – 0.78 N-m).     BUILT-IN I/O The I/O is mapped into OCS Register space, in three sep- arate areas – Digital/Analog I/O, High-Speed Counter I/O,  and High-speed Output I/O. Digital/Analog I/O location is  fixed starting at 1, but the high-speed counter and high- speed output references may be mapped to any open  register location.    NOTE: The 0V terminals are internally connected.   Digital and Analog I/O Functions Digital  ...
  • Page 7: Communications

    COMMUNICATIONS Serial Communication Dip Switches MJ1/2 Serial Ports MJ1/2 Independent Serial Ports     MJ1: RS-232 w/Full Handshaking  MJ2:   R S-485 Half-Duplex   MJ1 PINS MJ2 PINS SIGNAL DIRECTION SIGNAL DIRECTION DIP Switches NAME FUNCTION DEFAULT GROUND GROUND MJ3 RS-485  ON =  +5V   @    +5V   @    Termination Terminated 60mA 60mA ON = Half...
  • Page 8: Dimensions & Installation

    DIMENSIONS & INSTALLATION Dimensions & Panel Cutout Installation Procedure    1.  Carefully locate an appropriate place to mount the  OCS. Be sure to leave enough room at the top of the  unit for insertion and removal of the microSD™ card.  2.  Carefully cut the host panel per the diagram, cre- ating a 31.9mm x 175.0mm, with a +1mm/-0mm  opening into which the OCS may be installed. If the  opening is too large, water may leak into the enclos- ure, potentially damaging the unit. If the opening is  too small, the OCS may not fit through the hole  without damage.  3.  Remove any burrs and or sharp edges and ensure  the panel is not warped in the cutting process.  4.  Remove all Removable Terminals from the OCS.  Insert the OCS through the panel cutout (from the  front). The gasket must be between the host panel  and the EXL6.  5.  Install and tighten the four mounting clips (provided  in the box) until the gasket forms a tight seal. NOTE:  Max torque is 0.8 to 1.13Nm, or 7 to 10 in-lbs.  6.  Reinstall the   I /O Removable Terminal Blocks. Con- nect communications cables to the serial port, USB  ports, Ethernet port and CAN port as required.   ...
  • Page 9: Safety & Maintenance

    This device complies with Part 15 of the FCC Rules. Operation is  aging voltage potential between the laptop and controller.   subject to the following Ensure the controller       a nd laptop are grounded for max- two conditions: imum protection. Consider using a USB isolator due to        1.  This device may not cause harmful interference. voltage potential differences as a preventative measure.  2.  This device must accept any interference received, includ-   ing interference that may cause undesired operation.        Technical Support North America 1 (317) 916-4274 (877) 665-5666 www.hornerautomation.com techsppt@heapg.com   Europe +353 (21) 4321-266 www.hornerautomation.eu technical.support@horner-apg.com       Page 9...

This manual is also suitable for:

He-xpl1e2

Table of Contents