Download Print this page

Graco President 232204 Instructions-Parts List Manual page 7

Wall mount air–assisted packages

Advertisement

General Information
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. Refer to
Product Data Sheet 305899. If you supply your own
accessories, be sure they are adequately sized and
pressure-rated for your system.
Fig. 1 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
Prepare the Operator
All persons who operate the equipment must be
trained in the safe, efficient operation of all system
components as well as the proper handling of all fluids.
All operators must thoroughly read all instruction
manuals, tags, and labels before operating the equip-
ment.
The following manuals are included with this equip-
ment:
D 308757, Wall Mount Air-Assisted Packages
D 306981, President 30:1 CST Pump, or
308106, President 30:1 SST Pump, or
307619, Monark 23:1 CST and SST Pumps, or
306936, President 15:1 CST Pump, or
308106, Monark 15:1 SST Pump, or
308739, Monark 15:1 CST Pump
D 306982, President Air Motor, or
307043, Monark Air Motor
D 308686, Air Regulator Kit
D 307273, Fluid Filter
D 307886, Fluid Regulator (Models 232251, 232252,
232255, 232256)
D 311001, AA Series Spray Gun (Models 232204,
232215, 232226, 232237, 232244, 232251, and
232255 only)
Installation
Prepare the Site
NOTE: The compressed air supply to the gun must be
clean and dry, to prevent damage to the finish. Use a
coalescing air filter in the main air supply line.
Ensure that the wall is strong enough to support the
weight of the pump and accessories, fluid, hoses, and
stress caused during pump operation.
Ensure that you have an adequate compressed air
supply. Refer to the performance charts on page 25 to
find the air consumption of your pump.
Refer to Fig. 1. Bring a compressed air supply line
from the air compressor to the pump location. Be sure
all air hoses are properly sized and pressure-rated for
your system. Use only electrically conductive hoses.
The air hose (A) should have a 3/8 npsm(m) thread.
Install a bleed-type shutoff valve (B) in the air line to
isolate the air line components for servicing. Install an
air line filter (C) and a moisture trap and drain valve
(D) to help remove moisture and contaminants from
the compressed air supply.
Keep the site clear of any obstacles or debris that
could interfere with the operator's movement.
Have a grounded, metal pail available for use when
flushing the system.