  • Page 1 Technical Reference 020-103050-04 MicroTiles LED Serial Commands...
  • Page 2 Christie's control such as maintenance of the product in proper working conditions. Performance specifications are based on information available at the time of printing. Christie makes no warranty of any kind with regard to this material, including, but not limited to, implied warranties of fitness for a particular purpose.
  • Page 3: Table Of Contents

    Content Communicating with MicroTiles LED........5 Connection and use.
  • Page 4 WDM–Wall Dimension Window......... . 23 MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 5: Communicating With Microtiles Led

    MicroTiles LED Understand the information and procedures for communicating with MicroTiles LED from a remote location. You can communicate with the MicroTiles LED wall controllers through RS232 or Ethernet. Using RS232 requires a USB to RS232 dongle. Connection and use...
  • Page 6: Understanding The Message Format

    ASCII code (A-Z, upper or lower case). This function code appears immediately after the leading parenthesis that starts the message. In messages sent to MicroTiles LED that do not have a subcode, a space between the function code and the first parameter (or special character) is optional.
  • Page 7: Special Characters For Text

    (PWR!000). Data The value for a given MicroTiles LED state, such as on or off, appears in ASCII- decimal format directly after the request/reply symbol. You can add an optional space after the symbol—such as before the data—in a set message, but data in replies follow the exclamation mark (!) symbol without a space.
  • Page 8: Maximizing Message Integrity

    The acknowledgment is returned after the message has been received and fully executed by MicroTiles LED (such as in the case of a source switch it is not sent until the switch is complete). If the message cannot be executed for some reason (such as invalid parameters, time-out, and so on) a NAK is returned instead (not-acknowledge).
  • Page 9: Error Messages

    System busy - Try again later Product documentation For installation, setup, and user information, see the product documentation available on the Christie website. Read all instructions before using or servicing this product. 1. Access the documentation from the Christie website: •...
  • Page 10: Related Documentation

    MicroTiles LED Specifications Guide (P/N: 020-102836-XX) • MicroTiles LED Status System Guide (P/N: 020-103556-XX) • Replacing LED modules in a MicroTiles LED array (P/N: 020-103059-XX) • Removing the MicroTiles LED chassis (P/N: 020-102670-XX) MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright ©...
  • Page 11: Serial Api Commands

    Serial API commands The MicroTiles LED commands can be used to modify product settings. BRI–Array Brightness Sets the brightness of the array, from 0 to 100% of the array capacity. Commands Command Description Values BRI <value> Changes the array brightness.
  • Page 12: Drk-3D Dark Interval

    (Saved value) serial messages 1 = Enables asynchronous FYI/ERR serial messages (Default) MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 13: Gam-Gamma Power Value

    0 = Celsius (Default) 1 = Fahrenheit Examples Set the temperature to Fahrenheit: (LOC+TEMP 1) MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 14: Lwc-Led Wall Controller Count

    • <type> = 58 (fixed value) • <major>, <minor>, <build> = Software version MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 15: Pwr-Power

    200 - DP Stitched 201 - HDMI Stitched E1000-3D: 999 - Disable MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 16 4 = SDI Input 1 MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 17 Force the system to use the secondary input on the primary wall controller.: (SIN+OVRD 2) MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 18: Snm-Snmp Configuration

    = Indicates the condition of the status four-letter group identifier. item: MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 19: Szp-Aspect Ratio

    4 = Full Height (Stretched vertically) 6 = Custom (User defined canvas) MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 20: Tdd-3D Sync Delay

    Inverts the left and right eye frames. Only applies to: E1000 Active 3D wall controller MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 21: Til-Tiles Count

    0. Examples Display the number of tiles in the currently powered on array: (TIL+CURR) TMD–Time and Date Sets the display time and date for all devices in the MicroTiles LED array. Commands Command Description Values TMD+DATE <date>...
  • Page 22: Uid-User Id

    = String value Examples Log in as service: (UID "service" "<password>") MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.
  • Page 23: Vid-Refresh Rate Priority

    Set the height of the video output signal to 1080 pixels: (WDM+HGHT 1080) MicroTiles LED Technical Reference–Serial Commands 020-103050-04 Rev. 1 (03-2023) Copyright © 2023 Christie Digital Systems USA, Inc. All rights reserved. If printed, please recycle this document after use.