Safety Instructions: Installation - Endress+Hauser Liquiphant FTL51B Safety Instruction

Hide thumbs Also See for Liquiphant FTL51B:
Table of Contents

Advertisement

Liquiphant FTL51B
Safety
instructions:
Installation
Endress+Hauser
• Limitations of the maximum ambient temperature at the electronics
enclosure may be required dependent on device configuration,
process temperatures and temperature classification.
• Details of limitations: →  12, "Temperature tables".
• To avoid electrostatic charging: Do not rub surfaces with a dry cloth.
• In the event of additional or alternative special varnishing on the
enclosure or other metal parts or for adhesive plates:
• Observe the danger of electrostatic charging and discharge.
• Do not install in the vicinity of processes (≤ 0.5 m) generating
strong electrostatic charges.
• Avoid sparks caused by impact and friction.
Optional specification, ID Px, Rx = PA
Connect the weather protection cover to the local potential
equalization.
Optional specification, ID Px, Rx = PB
Avoid electrostatic charging of the weather protection cover (e.g.
friction, cleaning, maintenance, strong medium flow).
A
3
2
1
 1
A
Zone 1, Zone 21
1
Tank; Zone 0, Zone 1, Zone 20, Zone 21
2
Electronic insert
3
Enclosure
4
Associated intrinsically safe power supply units
5
Potential equalization line
6
Local potential equalization
XA03005F-A