The procedures must be are available and recommended as accessories. done by approved personnel only. Speak to Systemair for more information on how to install the Intended use product in different installation locations. DKEX fans, KTEX fans are used for transport of air or explo- sive atmospheres with a maximum temperature of 60 °C and...
Name plate Voltage, V IP class, enclosure class Ambient temperature 10. Speed controllable Systemair Sverige AB Industrivägen 3 739 30 Skinnskatteberg SE 11. Identification number of Notified Body www.systemair.com 12. Equipment group II is intended for use in areas with ex- plosive gas, except mining gas.
3–phase, 415 V 3–phase, 415 V Note: Information that is necessary in a given situation. Product liability Systemair is not liable for damages that the product causes Safety instructions in these conditions: • The product is incorrectly installed, operated or Warning maintained.
capabilities, or lack of experience and knowledge, unless Transportation and they have been given supervision or instruction. storage • Do not allow children to play with the product. Warning Personal protective Make sure that the product does not equipment become damaged or wet during transportation.
– To decrease vibrations transmitted from the product to protection is necessary that meet the the duct system, Systemair recommends to install vi- crosscut test parameter of 2 / EN ISO bration dampers, fast clamps or flexible connections.
Note: Measure the distance (A) between the product and Systemair recommends to use flexible connections to at- the duct bend. tach the duct to the product. Flexible connections are Make sure that the distance (A) is a minimum of 2.5 available as accessories.
Page 10
Guide rails are not supplied by creased air pressure: Systemair. Measure the distance (A) between the product and the duct bend. Note: Make sure that the distance (A) is a minimum of 2.5...
Increase the operation speed gradually to the maximum Operation operation speed. Examine the vibrations in the casing and the bearing To start the product areas at all speed levels. Make sure that the speed controller is set to position “0”. Make sure that the vibrations agree with the specifi- cations in DIN ISO 14694.
Maintenance Warning Set the installed safety switch in the OFF position before you do the maintenance unless the instructions tell you differently. Make sure that the safety switch is not accidentally set in the ON position. Maintenance schedule The intervals are calculated from continuous operation of the product. Maintenance task Usual operation Unusual operation conditions.
Troubleshooting Note: If you cannot find a solution to your problem in this section, speak to Systemair technical support. Problem Cause Solution The fan impeller is not correctly Speak to Systemair technical support. balanced. There is dirt on the fan impeller.
Connect the capacitor correctly. Refer correctly connected. to the included motor wiring diagram. There is blockage in the motor. Speak to Systemair technical support. Defective motor winding. If it is possible, measure the resistance to do a check of the motor winding.
• The instructions in the data sheets are obeyed. For warranty claims, send a written maintenance plan and • Maintenance instructions are obeyed. the commissioning report to Systemair. The warranty is only applicable for these conditions: • A product that is not operated continuously is operated for a minimum of 1 hour each month.
Min. static back pressure (Pa) Fan type Imax Cntrl.(A) 1.64 KTEX 50-25-4 0.95 3.27 KTEX 50-30-4 4.35 KTEX 60-30-4 KTEX 60-35-4 KTEX 70-40-6 3.76 Product dimensions Note: If the unit of measure is not specified, the dimensions are given in millimetres. Note: The arrow in the dimension drawing shows the direction of the airflow.
DKEX: Explosion proof fan VK: Louvre shutter USE: Flexible connection IGK: Wall grid Note: The selection of accessories shown are not supplied with the product. For more information and other available accessories, refer to www.systemair.com or speak to Systemair technical support.
DS: Flexible connection LDR: Silencer VK: Louvre shutter DS: Flexible connection IGK: Wall grid Note: The selection of accessories shown are not supplied with the product. For more information and other available accessories, refer to www.systemair.com or speak to Systemair technical support.
EU Declaration of Conformity We, the manufacturer Manufacturer Systemair Sverige AB Address Industrivägen 3 739 30 Skinnskatteberg Sweden declare under our sole responsibility that the products Machine Explosion proof fan Type/Model DKEX, KTEX fulfils the relevant provisions of following directives and...