Save Custom Keymap Command (KB)
Command number:
Description:
Data structure:
Result codes:
Example Save Custom Keymap Request (Hex):
Cmd Num
05
Example Save Custom Keymap Response (Hex):
Result Code
00
DUKPT Operation
Since key loading is proprietary and performed at MagTek, there are no user commands to
support key injection.
Get DUKPT KSN and Counter Command
Command number:
Description:
Data structure: No data is sent with this command.
Offset
Field Name
0
Current Key
Serial Number
Result codes:
0x05
This command is used to save the active key map as the custom key map
in non volatile memory. The active key map is determined by the active
key map property. Once a key map item is modified, the changes take
affect immediately. However, the changes will be lost if the reader is reset
or power cycled. To make the changes permanent, the save custom key
map command must be issued. To use the new custom key map after a
reset or power cycle, the active key map property must be set to custom.
Request Data: None
Response Data: None
0x00 Success
0x07 Incorrect MAC – Command not authorized
Data Len
00
Data Len
00
0x09
This command is used to report the Key Serial Number and Encryption
Counter.
Response Data:
Description
This eighty-bit field includes the Initial Key Serial
Number in the leftmost 59 bits and a value for the
Encryption Counter in the rightmost 21 bits.
0x00 Success
0x02 Bad Parameter – The Request Data is not the correct length. The
request command contains no data, so the Data Length must be 0.
Section 2. Communications
Data
Data