MagneSafe V5
00 01 20
; Get current Pre Track String
Request
: CMND=00, LEN=01, DATA=20
Response
: RC=
; Form MAC for Set Property command
;
Message to be sent is: 01 05 20 nnnnnnnn (nnnnnnnn is the MAC)
;
Message to be MACd is: 0105200000000000
;
This is the simplest MAC, simply TDES encrypt the message to be MACd with
;
the MAC Key:
;
0105200000000000 MACd with
;
gets
442A09E6588BBF04
;
MAC is first four bytes: 442A09E6
01 05 20 442A09E6
Request
: CMND=01, LEN=05, DATA=20 44 2A 09 E6
Response
: RC=
00 01 21
; Get current Post Track String
Request
: CMND=00, LEN=01, DATA=21
Response
: RC=
; Form MAC for Set Property command
;
Message to be sent is: 01 05 21 nnnnnnnn (nnnnnnnn is the MAC)
;
Message to be MACd is: 0105210000000000
;
This is the simplest MAC, simply TDES encrypt the message to be MACd with
;
the MAC Key:
;
0105210000000000 MACd with C3DF489FDF11ACB4 F03DE97C27DCB32F
;
gets
1FA9A44C703099E1
;
MAC is first four bytes: 1FA9A44C
01 05 21 1FA9A44C
Request
: CMND=01, LEN=05, DATA=21 1F A9 A4 4C
Response
: RC=
00 01 22
; Get current Termination String
Request
: CMND=00, LEN=01, DATA=22
Response
: RC=
; Form MAC for Set Property command
;
Message to be sent is: 01 06 22 0D nnnnnnnn (nnnnnnnn is the MAC)
;
Message to be MACd is: 0106220D00000000
;
This is the simplest MAC, simply TDES encrypt the message to be MACd with
;
the MAC Key:
;
0106220D00000000 MACd with 6584885077214CF1 4737FA93F92334D2
;
gets
381AD461F2BDC522
;
MAC is first four bytes: 381AD461
01 06 22 0D 381AD461
Request
: CMND=01, LEN=06, DATA=22 0D 38 1A D4 61
Response
: RC=
00 01 2C
; Get current Format Code
Request
: CMND=00, LEN=01, DATA=2C
Response
: RC=
; Form MAC for Set Property command
;
Message to be sent is: 01 09 2C 31303030 nnnnnnnn (nnnnnnnn is the MAC)
;
Message to be MACd is: 01092C3130303000
;
This is the simplest MAC, simply TDES encrypt the message to be MACd with
;
the MAC Key:
;
01092C3130303000 MACd with E161D1956A6109D2 F37AFD7F9CC3969A
;
gets
D153861529E88020
106
00, LEN=00, DATA=
; Set to ""
00, LEN=00, DATA=
00, LEN=00, DATA=
; Set to ""
00, LEN=00, DATA=
00, LEN=01, DATA=0D
; Set to "<ENTER>"
00, LEN=00, DATA=
00, LEN=05, DATA=31 FF FF FF FF
9CF640F279C251E6 15F725EEEAC234AF