Watts WFHC 06Z 02 HC RF 24 User Manual page 5

Water floor controller wireless

Advertisement

3.3
DIP switch configuration (In Orange)
DIPswitch
Function
number
DIP1
Controller
function
DIP2
Actuator types
DIP3
Pump
(After start / After
stop request)
DIP4 and
H&C
DIP5
control
DIP6
Anti Grip
DIP7
Humidity
management
DIP8
Humidity sensor
3.4
USB stick
USB connectivity allows
To update the Software of the controller.
To record data for system monitoring
For the software update, please refer to wattswater.eu for getting the file, put the file on an USB stick.
Insert the USB stick on the controller
Switch OFF/ON the controller
During update,
o
o
o
After update, you can remove the USB stick
Value
(default: OFF)
OFF
ON
OFF
ON
delays
OFF
ON
switch
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
Green LED are power on from Z1 to Z6/Z8
All LED become red
Red LED are power Off from Z6/Z8 to Z1
Configuration
Local Pump
Global pump
NC actuator
NO actuator
2min/5min
5min/20min
Central Unit
OFF
BT-CT02 RF
Master thermostat
ON
BT-D03 RF
OFF
WFC HCM RF
ON
H&C input
Enabled
Disabled
Comfort approach
Safety approach
ON/OFF sensor
Pipe temperature
sensor
5
Description
See 5.3
See 5.6
See 5.3
See 5.2
See 7.1
See 5.5
See 5.5