Configuration of the EK1914 in TwinCAT
PrmName
Bedeutung
Testing of outputs
Test pulses for the outputs are activated
active
Error acknowledge
True:
active
Bus Coupler errors lead to a reset of the TwinSAFE
connection (error code 14 (0x0E)). This error code is
shown in the diagnostic data for the connection until
the user acknowledges it via ErrAck in the TwinSAFE
group.
False (Default):
Bus Coupler errors can only be reset by switching the
power supply off and back on again.
Sensortest Kanal 1
The clock signal of the "Clock output safe input 1"
aktiv
connection is tested at the "Safe input 1" connection.
Sensortest Kanal 2
The clock signal of the "Clock output safe input 2"
aktiv
connection is tested at the "Safe input 2" connection.
Logik Kanal 1 und 2
Logic of channels 1 and 2
Store Code
This parameter is required for the TwinSAFE Restore
Mode.
Project CRC
This parameter is required for the TwinSAFE Restore
Mode.
Identity
These parameters are used internally only.
Detected Modules
These parameters are used internally only.
46
Version: 2.0.0
Werte
true / false
true / false
true / false
true / false
• single logic
• asynchronous repetition
OSSD (sensor test must be
switched off)
• any pulse repetition OSSD
(sensor test must be
switched off)
• Short cut is no module fault
-
-
-
-
EK1914