Installation
Use suitable mounting rail fastening
The locking mechanism of the TwinSAFE terminals and the EtherCAT Coupler extends into the
profile of the mounting rail. When mounting the components, ensure that the locking mechanism
does not come into conflict with the mounting screws of the mounting rail. Use flat mounting
connections such as countersunk screws or blind rivets to fasten mounting rails with a height of 7.5
mm under the terminals and couplers.
Disassembly
Fig. 8: Removal from mounting rail
Each TwinSAFE terminal is secured on the mounting rail by a latch. For disassembly, the locking of the
TwinSAFE terminals must be released as follows:
4. Pull the TwinSAFE terminal down approx. 1 cm from the mounting rail by the orange-colored tab. The
mounting rail lock of the TwinSAFE terminal is released automatically.
5. Grip the unlocked TwinSAFE terminal simultaneously at the top and bottom of the housing surfaces with
thumb and index finger.
6. Pull the TwinSAFE terminal out of the Bus Terminal block with little force.
28
Version: 2.0.0
EK1914