Tested devices

The following list contains devices that were tested together with the EK1914 TwinSAFE Bus Coupler. The
results only apply for the current device hardware version at the time of testing. The tests were carried out in
a laboratory environment. Modifications of these products cannot be considered here. If you are unsure, test
the hardware together with the TwinSAFE Bus Coupler.
The tests were carried out as function tests only. The information provided in the respective manufacturer
documentation remains valid.
Sensors
Manufacturer Type
SICK
C4000
SICK
S3000
Wenglor
SG2-14ISO45C1
Leuze
lumiflex ROBUST 42/43/44
Schmersal
BNS250-11ZG
ifm
GM701S
Keyence
SL-V (with PNP cable set)
Actuators
Manufacturer
Type
Beckhoff
AX5801
Siemens
SIRIUS Serie S00
3RT1016-1BB42
Recommended protective circuits
For actuators, we recommend R/C or diode protective circuits. Varistor protective circuits should not be
used.
EK1914
Comment
Safety light curtain
Safety light scanner
Safety light grids
Safety light barriers
Safety switch
Inductive safety sensor
Safety light curtain
Comment
TwinSAFE Drive option card: safe restart lock
Contactor