Skytron 3600B UltraSlide Operator's Manual

Skytron 3600B UltraSlide Operator's Manual

Surgical table
Hide thumbs Also See for 3600B UltraSlide:

Advertisement

Quick Links

SURGICAL TABLE
OPERATORS MANUAL
3600B UltraSlide
REV 8/05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3600B UltraSlide and is the answer not in the manual?

Questions and answers

Summary of Contents for Skytron 3600B UltraSlide

  • Page 1 SURGICAL TABLE OPERATORS MANUAL 3600B UltraSlide REV 8/05...
  • Page 3: Table Of Contents

    SECTION III MAINTENANCE ....................... 22 3-1. Preventive Maintenance ..................... 22 3-2. Cleaning Recommendations ....................22 3-3. Service ..........................23 REV 8/05 Although current at the time of publication, SKYTRON’s policy of continuous development makes this manual subject to change without notice.
  • Page 4: Equipment Labels And Specifications

    Page 2 EQUIPMENT LABELS AND SPECIFICATIONS INDICATES DANGEROUS VOLTAGE, 120 V, 60 Hz CLASS I DEFIBRILLATION PROOF, TYPE B EQUIPMENT- IPX4 RATED. INTERNALLY POWERED EQUIPMENT TYPE B EQUIPMENT PROTECTIVE GROUNDING. IN ORDER TO ENSURE PROPER GROUNDING RELIABILITY, THIS TABLE MUST BE CONNECTED TO A PROPERLY GROUNDED HOSPITAL GRADE OUTLET.
  • Page 5: 3600B Ultraslide General Purpose Surgical Table Specifications

    Page 3 3600B UltraSlide General Purpose Surgical Table Specifications 14-1/2" 12-1/2" 18-1/4" 25" 23" 14-1/2" 19-3/4" TOP VIEW 82" 60˚ 5-3/4" 22" 3" 90˚ 42-1/2" MAX 24" MIN 5-3/4" 8-3/4" 19" 40-3/4" SIDE VIEW END VIEW ENTELA CERTIFIED Electrical Specifications...
  • Page 6: Special User Attention

    Page 4 SPECIAL USER ATTENTION The extreme positioning capabilities of the 3600B NOTE UltraSlide Table requires special attention for pos- sible interference points when using multiple func- Activating any function button will acti- tion positioning. As with the operation of any vate the brake system.
  • Page 7 SPECIAL USER ATTENTION Page 5 NOTE NOTE The charging system operates ONLY If the table top is slid toward the foot when the table is in AC120V operation end, the back section will not go below mode. horizontal. An audible alarm will sound. NOTE NOTE The table can be operated on 120VAC...
  • Page 8 Page 6 SPECIAL USER ATTENTION NOTE NOTE The emergency back-up control If the top is slid toward the foot end, the switches will function when the table is FLEX function will not operate. An operating on 120VAC power, battery audible alarm will sound. power, or turned off.
  • Page 9 WARNING Certain accessories may limit weight capacities. Check with your SKYTRON representative. NOTE Always follow current AORN Journal Guidelines to ensure proper cleaning and disinfection procedure.
  • Page 10: Section I Introduction

    SWITCH Figure 1-1. 3600B UltraSlide 1-1. General main power ON/OFF switch is located on the SKYTRON’s 3600B UltraSlide Surgical Table is an electrical panel on the front edge of the table base. electro-hydraulically operated, general purpose sur- See figure 1-2.
  • Page 11: Pendant Control Unit

    Page 9 1-3. Pendant Control Unit The function push buttons are identified with ab- The hand-held pendant control unit (figure 1-3) breviated descriptions for all functions. See figure has a non-slip rubber cover which assures a posi- 1-5. When illuminated the Trendelenburg and tive grip during use.
  • Page 12: Section Ii Operation

    Page 10 SECTION II OPERATION 2-1. Electrical Power The 3600B table will operate on either 120 VAC or battery power. WARNING Prior to operating the table, observe all table caution labels and review the SPECIAL USER ATTENTION section MAIN POWER FOOT CONTROL in the front of this manual.
  • Page 13: Battery Operation

    Page 11 2-3. Battery Operation 2-5. Charging the Battery a. Make sure the Main Power Switch indicator Batteries should be charged: light, on the electrical panel, are OFF. See figure • When the table is placed into initial 2-2. If the indicator light is ON, turn AC120V service operation OFF with the main power switch.
  • Page 14: Positioning Functions

    Page 12 2-6. Positioning Functions b. If the battery needs to be charged when operating the table on battery power, the red indi- The hand-held pendant control (figure 2-4) acti- cator light on the pendant control will begin to blink. vates the following table functions: NOTE AC120V POWER ON...
  • Page 15: Trendelenburg

    Page 13 Press the BRAKE UNLOCK button on the pendant REVERSE control to release the four self-leveling brake feet in TRENDELENBURG TRENDELENBURG order to move the table. See figure 2-5. The brake delay circuit automatically retracts the brake sys- tem. It takes approximately 7-8 seconds to totally release the system.
  • Page 16: Back Section

    Page 14 d. Back Section. To raise the back section, press the BACK UP button (figure 2-8). The back section will raise up to 90° above horizontal. To TABLE lower the back section, press the BACK DOWN TABLE DOWN button. The back section will go down to 40° below horizontal.
  • Page 17: Leg Section

    Page 15 SLIDE FOOT SLIDE HEAD LEG DOWN LEG UP 9-1/2" 13-1/2" 15˚ 100˚ Figure 2-10. Top Slide Figure 2-11. Leg Section Positioning g. Leg Section. To lower the leg section, press h. Flex Positioning. To place the table top in the LEG DOWN button (figure 2-11).
  • Page 18: Kidney Lift

    Page 16 i. Kidney Lift. To raise the built-in kidney lift, press the KIDNEY UP button (figure 2-13). Up to 5-3/4" of lift can be achieved. Press the KIDNEY DOWN button to lower the kidney lift. NOTE To prevent damage to the kidney lift, a RETURN safety interlock prevents the kidney lift TO LEVEL...
  • Page 19: Emergency Back-Up Controls

    Page 17 2-7. Emergency Back-up Controls a. The emergency back-up control switches are located under the access door on the service access cover in the table base. See figure 2-16. CAUTION The EMERGENCY BRAKE LOCK switch does not activate the brake sys- tem timer.
  • Page 20: Emergency Brake Release

    The Emergency Brake Release Valve must be closed and tightened (clock- 3600B UltraSlide Table has the capability of at- wise) before activating any function. taching the head section to the leg section for use as a foot extension ONLY.
  • Page 21: Leg And Back Section Removal

    The use of certain optional accessories available sure the release levers are completely locked. from SKYTRON further extend the positioning capabilities of the 3600B UltraSlide Table. Refer to d. To install the Back Section if the attachment the following "Positioning Guidelines" or contact pins are not aligned, make sure the table top is your SKYTRON representative for further details.
  • Page 22 Page 20 UltraSlide 3600B Bariatric Recommended Patient Positioning Abdominal Laparoscopic Gastric Bypass Cysto/GYN UltraSlide 3600B Positioning Guidelines Upper Body Imaging Lower Body Imaging Lap Nissen Urology...
  • Page 23 Page 21 Ophthalmic/ENT Nephrectomy Neuro (neck) Neuro (lumbar) Shoulder Arthroscopy Lumbar Endovascular (with optional 48” Carbon Orthopedic (with Traction Accessories) Fiber Leg Extension)
  • Page 24: Section Iii Maintenance

    3-2. Cleaning Recommendations The following preventive maintenance checks and services are recommended to ensure the service- NOTE ability and proper operation of your SKYTRON Surgical Table, and should only be performed by Always follow current AORN Journal qualified SKYTRON trained personnel.
  • Page 25: Service

    To obtain service instructions, replacement parts, spray fluids directly into electrical re- factory service or preventive maintenance con- ceptacles or micro switches. tracts, contact the SKYTRON representative listed below. Repeat cleaning procedure for all table surfaces including the top, sides, elevation column, base and all accessories.
  • Page 28 5000 36th Street S.E., Grand Rapids, MI 49512 1-800-SKYTRON or 1-616-957-0500 • FAX 1-616-957-5053...