Operation
- Editing Rotor Data
5 - 8
5.2.12 Setup Rotor Data - Units and Toler-
ances
Main menu \ Rotor settings.
Select "Units & Tolerances" tab.
Enter values or change settings:
Tolerance Setup
Enter balancing tolerances and cor-
rection limits.
Tolerance target
Enter balancing tolerance separately
for plane 1, plane 2, for static unbal-
ance and for couple unbalance.
Select tolerance unit by clicking into
one of the unit fields and, if required,
select a new unit.
Workpiece with smaller unbalance
values than the preset tolerance limit
are within tolerance.
Lower correction
Values generally smaller than the as-
limit
sociated tolerance limit. Workpieces
with larger unbalance have to be cor-
rected.
Upper correction
Workpieces with larger unbalance are
limit
rejected.
Quality calculation
The tolerance limits are calculated
based on the values entered for qual-
ity class, rotor mass, nominal rotor
speed and mass distribution of
planes.
Press the "Use Quality calculation"
key.
Setup Units
Select units for unbalance, tolerance
limits etc.
Press the "Apply" key.
MC10 HS