Basic Operation
- Unbalance plotting
A
Fig. 4-5: Unbalance plotting
4 - 18
Polar graph
Press the "Unbalance Plotting" key.
Note "ATTENTION: Run-up / Run-down" is dis-
played.
Press "Polar" (A) key.
1
1 - Indication of unbalance amount and angle,
type of calibration, direction of rotation, rotation-
al speed

2 - Command Keys

3 - Indication of unbalance in polar graph (plane 1)
4 - Indication of selected unbalance size in polar
graph (plane 2)
5 - Indication of currently selected rotor and status
display

6 - Command Bar

1/min (RPM)
1f
2f
2
Indicator
RH / LH rotation
Indicator
Currently measured speed
Indicator
direct speed
optional - double sample rate
for diagnosis
MC10 HS
3
4
5
6