Outlet Thermostat - Haier GE UltraFresh GFD55ESSN Technical Service Manual

Table of Contents

Advertisement

2. Disconnect the thermistor harness connector.
3. Remove one 1/4-inch hex-head screw
securing the thermistor to the supply duct and
pull out from the blower housing.
1/4" Hex-
Head

Outlet Thermostat

The outlet thermostat is located on the side of the
blower housing on both gas and electric models.
On gas and electric dryers, it opens at 165°F and
closes at 155°F.
Outlet Thermostat Diagnosing
Continuity can be checked at the thermostat or
from the main board. From the main board on the
electric dryer, check from the common terminals
of K502 or K501 relays to the line one side of the
power cord or terminal block. NOTE: Disconnect
the J101 connector from the main board to
prevent a false reading. If there's no continuity
found, either the outlet or inlet backup thermostat
could be open as they are in the same circuit.
– 47 –
Outlet
Thermostat
(Continued next page)