Translation of the original operating instructions
Test leak for sniffer leak detection
with Checkport
Catalog No.
12329
From software version
--
lini10en1-01-(2004)

Advertisement

Table of Contents
loading

Summary of Contents for Inficon 12329

  • Page 1 Translation of the original operating instructions Test leak for sniffer leak detection with Checkport Catalog No. 12329 From software version lini10en1-01-(2004)
  • Page 2 INFICON GmbH Bonner Strasse 498 50968 Cologne, Germany...
  • Page 3: Table Of Contents

    INFICON Table of contents Table of contents 1 About this manual.................... 4 1.1 General information .................. 4 1.2 Intended use .................... 4 1.3 Basic safety instructions ................ 4 1.4 Warnings..................... 6 2 Description...................... 7 2.1 Calibrated test leak with Checkport ............ 7 2.2 Technical specifications................ 9 3 Calibrate ......................
  • Page 4: About This Manual

    1 | About this manual INFICON 1 About this manual 1.1 General information The calibration leak must only be operated in the proper condition and in the condition described in the instruction manual, and used by trained personnel. Follow the local regulations for the use of the calibration leak.
  • Page 5 • Calibration gas: Avoid eye-contact and inhalation in high concentrations. • Share the security information with other users. INFICON does not assume any responsibility and warranty if the operator or third parties • disregard this document • use the product for purposes other than those for which it was intended •...
  • Page 6: Warnings

    1 | About this manual INFICON 1.4 Warnings DANGER Imminent hazard resulting in death or serious injuries WARNING Hazardous situation resulting in potential death or serious injuries CAUTION Hazardous situation resulting in minor injuries NOTICE Hazardous situation resulting in damage to property...
  • Page 7: Description

    The calibrated test leak is installed in a rectangular housing. It has two outlets for calibration gas. The lower outlet is for calibration, the lower gas flow from the upper outlet should be detected by your INFICON leak detector at highest sensitivity. Sniffer-calibration-leak-Checkport-Operating-instructions-lini10en1-01-(2004) 7 / 15...
  • Page 8 2 | Description INFICON Fig. 1: Test leak with test measuring point 1 Checkport (test 2 Manometer measuring point detection limit) 3 Date of calibration 4 Leak rate of the calibrated test leak. 5 Calibration (outlet of the calibration gas) 8 / 15...
  • Page 9: Technical Specifications

    INFICON Description | 2 2.2 Technical specifications Note that the pressure in the test leaks changes depending on the temperature. Smallest deviation from calibration ± 10 % Cat. No. / Pressure range 123 29 approx. 3 bar Temperature range +15°C to +35°C Storage temperature 0°C to +40°C...
  • Page 10: Calibrate

    3 | Calibrate INFICON 3 Calibrate The calibrated test leak constantly emits gas during its operational readiness. WARNING Explosive gas mixtures Flammable gases can form explosive gas mixtures, see the gases marked with the flame symbol under “Technical specifications“. ► Care for sufficient ventilation and keep away from ignition source.
  • Page 11: Cleaning And Maintenance

    The calibrated test leak requires no maintenance. When the calibration gas is used up, the test leak has to be refilled and calibrated. Contact your nearest INFICON service point. 4.3 Sending for repair or maintenance Do not open defective products.
  • Page 12 4 | Cleaning and maintenance INFICON CAUTION Calibration gas Test leaks sent for repair may still contain calibration gas. ► Take account of the national regulations for shipping the respective calibration gas. 12 / 15 Sniffer-calibration-leak-Checkport-Operating-instructions-lini10en1-01-(2004)
  • Page 13: Disposal

    INFICON Disposal | 5 5 Disposal WARNING Environmentally hazardous substances Products, equipment, etc. may have to be disposed of specially. ► Contact your nearest INFICON service center for correct disposal. Sniffer-calibration-leak-Checkport-Operating-instructions-lini10en1-01-(2004) 13 / 15...