Chassis dimensions

System operating environment

Power supply

Rack and cabinet mounting options

N
TPS 3D S
ORTEL
ENSOR AND
The
Chassis Dimensions table

Chassis Dimensions

Dimension
Metric
Height
43 mm
Width
445 mm
Depth
574 mm
This section describes the required office environment for the TPS 2070 DC.
Environmental parameters
Keep the TPS 2070 DC in an environment that meets the specifications in the
Environmental Parameters
Environmental Parameters
Parameter
Operating temperature
Non-operating temperature
Operating humidity
The sensor power supply is rated for 400 watts.
The TPS 2070 DC can be used in racks and server cabinets that are 19 inches
wide and up to 30 inches deep. The sensor comes with a rack-mount kit. Refer to
the instructions that are supplied with the sensor for more information about
correctly mounting the chassis in a rack.
D
C
I
EFENSE
ENTER
NSTALLATION
Chapter 3: Hardware specification
lists the dimensions of the chassis.
Imperial
1.7 inches
16.7 inches
25.6 inches
table.
Limits
10°C to 35°C (50°F to 95°F)
-40°C to +70°C (-40°F to +158°F)
8% to 90% non-condensing