Room temperature controller
Table of Contents

Advertisement

Fig. 24:
Parameters of channel (example illustration)
Pos.
[1]
[2]
[3]
[4]
[5] + [6]
[7]
[8]
[9]
Product manual 2CKA001373B8563
9
Description
Device name
This device name will be displayed.
Position
The selected position of the device is displayed.
Illustration
Here the device is illustrated.
Sensor configuration
Here you can block or release the local operation of the device.
Incoming and outgoing links
Under the "Links", you can create, delete or edit links. You can also see for which
devices a link was created. A difference is made between links of channels and scenes.
A list opens when tapping the plus icon in front of the channel or scene. Create the
desired link in the list by tapping the desired device.
The link can be deleted again by tapping on the dustbin icon.
Function
Select a function for the device. The default setting is "Room tempererature controller
with fan speed level". If you select the function without fan speed levels, it is not
possible to set the fan speed levels. In this case, no icons for setting the fan speed
levels are displayed on the device.
Time programs
This overview displays all previously created time programs. The number after a time
program indicates how often the actuator is used in this time profile. Select a time
program for adding to the actuator.
Parameters
Eco temperature reduction [°C]
The −/+ buttons can be used to specify by how many degrees the temperature is to be
reduced to when ECO mode is activated.
Temperature correction [°C]
Manual increase/reduction of the temperature value via the -/+ buttons to adjust a
permanent temperature offset.
Presence detector timed on duration [s]
If the ECO mode is deactivated by a movement detector, the switch-off delay can be
specified here when the ECO mode is to be re-activated after the room is exited.
Use of internal/external temperature reading
Notice: Only available in connection with an external temperature sensor.
The following selection options are available for the temperature reading.
Internal for regulating:
Commissioning