Commissioning; Allocation Of Devices And Definition Of Channels - ABB Caldion FCR-F-2-4.2.21.1 Series Product Manual

Room temperature controller
Table of Contents

Advertisement

6

Commissioning

Commissioning of the device is always carried out via the Web-based surface of the System
Access Point. It is assumed that the basic commissioning steps of the overall system have
already been carried out. Knowledge about the Web-based commissioning software of the
System Access Point is assumed.
The System Access Point establishes the connection between the free@home participants and
the smartphone, tablet or PC. The System Access Point is used to identify and program the
participants during commissioning.
Devices which are physically connected to the free@home bus, log themselves automatically
into the System Access Point. They transmit information about their type and supported
functions (See "Functions" on page 11).
During initial commissioning all devices are given a universal name, e.g. "Sensor/switch
actuator 1/1gang". The installer should assign names that are practical and specific for the
system, e.g. in "Living room ceiling light".
The devices can be parameterised for the use of additional functions.
Notice
General information about commissioning and parameterization is available in
the ABB-free@home
6.1

Allocation of devices and definition of channels

The devices connected to the system must be identified, i.e. they are allocated to a room
according to their function and are given a name.
The allocation is carried out via the Web-based user interface of the System Access Point.
 
Product manual 2CKA001373B8563
®
system manual.
Commissioning