DISASSEMBLY INSTRUCTIONS

This section is for reference, the images may differ from your actual unit.
N0.
PART NAME
1
FAN ASSEMBLY
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
PROCEDURES
REMOVE THE FAN
1. Turn off the air conditioner.
2. Turn off the power breaker.
3. Remove the 4 screws of the air outlet grille.
4. Remove the hex nut securing the fan.
5. Remove the fan.
6. Remove the top cover screws.
7. Remove the top cover.
8. Remove the electrical control box cover.
9. Disconnect the fan motor connector CN14 (3p,white) from
the IPM board.
10. Remove the fan motor after unfastening four fixing
screws.