Troubleshooting:
Description
Cause
No water
The battery is flat
Water supply
Water supply blocked
Water pressure too low
Water will not turn off
Dirty sensor window
Insufficient flow
Water supply pressure is
adjusted too low.
Inline filter is blocked
Too much water
Water supply adjusted
too high.
Short battery life
Incorrect battery
Indicator light off
Light broken
Circuit board or signal line wet
The battery is flat
Poor battery connection
Resetting the sensor range
Place your hand in the sensor field at the desired distance.
Briefly, place a strong magnet near the end of the spout, adjacent to, but not blocking, the
sensor window. The sensor will flash for 5 seconds, water will flow, and the distance is reset
as the water turns off. Repeat when required.
Care and Cleaning:
Never use abrasives or abrasive cleaning agents to clean this product. Clean
•
regularly with contamination free warm soapy water and a damp soft cloth.
WARNING
To avoid reflection problems keep a distance of more than 350 mm.
•
between the washbasin and the spout.
•
This outlet model, with an infrared sensor pointing down, is not
intended to be used together with a washbasin of a reflective material
such as stainless steel.
•
If a washbasin strainer is straight below the outlet sensor, use a
strainer with a non reflective finish (do not use a chrome plated one).
Methven warrants this product against manufacturing defects and that it is suitable for use
under the general operating conditions specified in this instruction sheet. However, regional
regulations apply and may affect your warranty. Please refer to www.methven.com or call
customer service for full details.
New Zealand
0800 804 222
1300 638 483
Treatment
Change the battery
Check the supply
Check the inline filter
Increase the water pressure
Clean the sensor window
Check the supply
Check the inline filter
Adjust the supply
Use 4 x AA / IEC-LR6 1.5V
Change the light or circuit board
Dry the board
Replace batteries
Check the connection
Min 350mm.
Bottom of the washbasin
Australia
0800 195 1602
Sensor Wall Tap
Installation Guide
Technical Specifications:
Operating Pressure:
Min: 150kPa/1.5bar
Max: 600kPa/6bar*
Optimum: 250kPa/2.5bar
Operating Temperature:
Hot: Max 55°C*
Cold: Min 5°C
Recommended: 38°C
Inlet Connection:
½" BSP female
Power:
DC: 6V (4 AA alkaline batteries)
AC: 220V - 240V; 50/60Hz
Sensing Distance: 50 - 250mm
* Regional specific regulations apply.
Please refer to your warranty statement
at www.methven.com
UK
ISSUE B
www.methven.com