23
Adjusting the Burn Rate
Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Air Control Settings
The settings listed below are the air control settings as performed for the EPA testing. Real-world
conditions such as chimney height and outdoor temperatures may cause these settings to vary. Use the
settings below to get close and then fine-tune the setting as needed to achieve the desired performance
from the stove.
High Burn:
Medium-High Burn:
Medium-Low Burn:
Low Burn:
The air control may become hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you
may wish to let the stove burn for 10 minutes to gauge performance.
© Travis Industries
Operation
Fully open (fully pulled out)
19/64" from full closed (fully pushed in) to fully open (fully pulled out)
11/64" from full closed (fully pushed in) to 19/64" from closed
Full Closed (fully pushed in) to 11/64" from full closed
1/12/2023 - 1574
Endeavor NexGen-Hybrid