Travis Industries Endeavor Manual

Freestanding
Table of Contents

Advertisement

Quick Links

OMNI-Test Laboratories, Inc.
EPA Standard of Performance for New Residential Wood Heaters
Certification Test Report
Manufacturer:
Heater Type:
Prepared for:
Prepared by:
Test Period:
Report Issued:
Report Number:
All data and information contained in this report are confidential and proprietary to Travis Industires,
Inc. Its significance is subject to the adequacy and representative character of the samples and to the
comprehensiveness of the tests, examinations, or surveys made. The contents of this report cannot be
copied or quoted, except in full, without specific, written authorization from Travis Industires, Inc. and
OMNI-Test Laboratories, Inc. No use of the OMNI-Test Laboratories, Inc. name, logo, or registered
mark (O-TL) is permitted, except as expressly authorized by OMNI-Test Laboratories, Inc. in writing.
Confidential Business Information
Travis Industries, Inc.
Freestanding Wood Stove
Endeavor
Model:
Travis Industries, Inc.
4800 Harbour Pointe Blvd SW
Mukilteo, WA 98275
USA
OMNI-Test Laboratories, Inc.
13327 NE Airport Way
Portland, OR 97230
(503) 643-3788
January 8-10, 2019
March 9, 2019
0028WS062E
- Document Edition # 001 (7/12/19) -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Endeavor and is the answer not in the manual?

Questions and answers

Summary of Contents for Travis Industries Endeavor

  • Page 1 OMNI-Test Laboratories, Inc. EPA Standard of Performance for New Residential Wood Heaters Certification Test Report Confidential Business Information Travis Industries, Inc. Manufacturer: Freestanding Wood Stove Heater Type: Endeavor Model: Travis Industries, Inc. Prepared for: 4800 Harbour Pointe Blvd SW Mukilteo, WA 98275 OMNI-Test Laboratories, Inc.
  • Page 2 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E AUTHORIZED SIGNATORIES This report has been reviewed and approved by the following authorized signatories: Evaluator: __________________________ Bruce Davis, Technician OMNI-Test Laboratories, Inc. Reviewer: ___________________________ Alex Tiegs, President OMNI-Test Laboratories, Inc. OMNI-Test Laboratories, Inc.
  • Page 3: Table Of Contents

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E TABLE OF CONTENTS PREFACE ....................... (3 pages) SAMPLING PROCEDURES AND TEST RESULTS............4 Introduction ..........................5 Individual Run summaries ....................6 Summary Tables Table 1 - Particulate Emissions Results ................7 Table 2 - Particulate Emissions Results (First Hour)............7 Table 3 –...
  • Page 4: Sampling Procedures And Test Results

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Section 1 Sampling Procedures and Test Results Page 4 of 186...
  • Page 5: Introduction

    Particulate emissions used in the weighted average were sampled on only one of the high burn fuel loads, test 5 was conducted to generate a coal bed for test number 6. The Endeavor results are within the emission limit of 2.5 g/h for affected facilities tested with cordwood, manufactured on or after May 15, 2020.
  • Page 6: Individual Run Summaries

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E INDIVIDUAL RUN SUMMARIES Test procedures followed to produce a high burn rate with a primary air setting of Run 1 - fully open. Observed burn rate was calculated at 5.06 kg/hr. Emissions results were calculated using particulate sampling from kindling, start-up fuel, and test fuel load combined (cold to hot).
  • Page 7 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Table 1 – Particulate Emissions Burn Rate ASTM E3053 ASTM E3053 Weighted Calculated from a Weighting Factor Emissions Hot to Hot burn ASTM E2515 (g/h) cycle Emissions (kg/h dry) (g/h) 5.06 3.63 0.726 1.69...
  • Page 8 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Table 4 – Test Facility Conditions Room Temperature Barometric Pressure Air Velocity (°F) (Hg) (ft/min) Before After Before After Before After 29.98 29.94 <50 <50 29.92 29.82 <50 <50 29.72 29.68 <50 <50 29.68...
  • Page 9 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Table 6 – Fuel Measurement and Cordwood Description Summary – TEST Douglas Fir Cordwood Test Fuel Firebox Fuel Loading Test Fuel Consumed Volume Test Fuel Density Wet Dry Basis During Test Piece Wet Basis...
  • Page 10 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Table 10 – Test Configurations Startup Procedures Combustion Air Fuel Loading: Kindling and start-up fuel loaded together, a torch was used for 15 seconds to establish a fire. At 58 minutes placed fuel load into the firebox and closed the loading door.
  • Page 11 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Fuel Loading: Test fuel loaded onto coal bed generated by test number 5 by 28 seconds. Door: Closed by 100 seconds. Fully open for first Primary Air: Fully open, then set to 1/2” by 7.0 minutes.
  • Page 12: Photographs/Appliance Description/Drawings

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Section 2 Photographs/Appliance Description/Drawings OMNI-Test Laboratories, Inc. Page 12 of 186...
  • Page 13 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Travis Industries, Inc. Endeavor Test Dates: Jan 8, 2019 – Jan 10, 2019 OMNI-Test Laboratories, Inc. Page 13 of 186...
  • Page 14 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Travis Industries, Inc. Large Flush Wood Hybrid Fyre Insert Run 1 – Kindling and start-up fuel Run 1 Kindling and start-up fuel Run 1 – Ignition of kindling Run 1 Fuel load OMNI-Test Laboratories, Inc.
  • Page 15 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Travis Industries, Inc. Large Flush Wood Hybrid Fyre Insert Run 1 – Remaining Start Up Fuel Run 1 Test Fuel Load In Stove Run 2 – Coal Bed Prior To Loading Run 2 Test Fuel Load OMNI-Test Laboratories, Inc.
  • Page 16 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 2 – Test Fuel Loaded into Stove Run 2 Remaining Coal After Test Run 3 – Kindling and start-up fuel Run 3 Ignition of kindling OMNI-Test Laboratories, Inc. Page 16 of 186...
  • Page 17 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 3 – Test Fuel Load Run 3 – Test Fuel Loaded into Stove Run 3 - Remaining Coal After Test Run 4 – Test Fuel Load OMNI-Test Laboratories, Inc. Page 17 of 186...
  • Page 18 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 4 – Test Fuel Loaded into Stove Run 4 - Remaining Coal After Test Run 5 Ignition of kindling Run 5 – Test Fuel Loaded into Stove OMNI-Test Laboratories, Inc. Page 18 of 186...
  • Page 19 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 5 - Remaining Coal After Test Run 6 – Test Fuel Load Run 5 – Test Fuel Loaded into Stove Run 6 - Remaining Coal After Test OMNI-Test Laboratories, Inc. Page 19 of 186...
  • Page 20 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E WOOD HEATER DESCRIPTION Appliance Manufacturer: Travis Industries, Inc. Wood Stove Model: Endeavor Type: Freestanding Non-Catalytic Wood Fired Room Heater WOOD HEATER INFORMATION Materials of Construction: The unit is constructed primarily of mild steel. The firebox is lined with fire brick that measures 4.5”...
  • Page 21: Test Data By Run

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Section 3 Test Data by Run OMNI-Test Laboratories, Inc. Page 21 of 186...
  • Page 22 Page 22 of 186...
  • Page 23 Page 23 of 186...
  • Page 24 Page 24 of 186...
  • Page 25 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Travis Industries, Inc. Large Flush Wood Hybrid Fyre Insert Test Dates: Jan 8, 2019 – Jan 10, 2019 OMNI-Test Laboratories, Inc. Page 13 of 186...
  • Page 26 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Results Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.37 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 193.8...
  • Page 27 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Results Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.37 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 193.8...
  • Page 28 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Results Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.37 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 193.8...
  • Page 29 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Results Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.37 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 193.8...
  • Page 30 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Results Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.37 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 193.8...
  • Page 31 OMNI-Test Laboratories, Inc. Wood Heater Lab Data Manufacturer: Travis Indusstries Equipment Numbers: Model: Endeavor Tracking No.: 2337 Project No.: 0028WS062E Run #: 1 Date: 1/8/19 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe Weights or Dish # Final, mg Tare, mg Particulate, mg B.
  • Page 32 OMNI-Test Laboratories, Inc. Wood Heater Test Results Manufacturer: Travis Indusstries Model: Endeavor Project No.: 0028WS062E Tracking No.: 2337 Run: 1 Test Date: 01/08/19 Burn Rate 4.39 kg/hr dry Average Tunnel Temperature 142 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 17.37 feet/second...
  • Page 33 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method - May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators - 10 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 34 Page 34 of 186...
  • Page 35 Page 35 of 186...
  • Page 36: Run 1

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 1 High Burn 10-minute data Efficiency and Heat Output Results Kindling and start-up fuel removed from calculations OMNI-Test Laboratories, Inc. Page 36 of 186...
  • Page 37 OMNI-Test Laboratories, Inc. Wood Heater Test Data Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 38 OMNI-Test Laboratories, Inc. Wood Heater Test Data Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 39 OMNI-Test Laboratories, Inc. Wood Heater Test Data Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 40 Wood Heater Efficiency Results - CSA B415.1 Manufacturer: Travis Indusstries Technician Signature: Endeavor Model: 01/08/19 Date: Run: Control #: 0028WS062E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 74.0% 80.0% Overall Efficiency 97.5% 97.5%...
  • Page 41 VERSION: 2.2 12/14/2009 Manufacturer: Travis Indusstries Appliance Type: Non-cat Model: Endeavor Date: 1/8/2019 Temp. Units (F or C) Run: 1 Weight Units (kg or lb) Control #: 0028WS062E Test Duration: 95 Output Category: IV Fuel Data D. Fir Wood Moisture (% wet): 17.50...
  • Page 42 14.10 0.80 14.97 547.0 73.0 13.80 0.76 14.93 550.0 73.0 13.50 0.71 14.87 549.0 72.0 13.10 0.71 15.00 549.0 73.0 12.80 0.69 14.98 547.0 73.0 12.40 0.65 14.98 545.0 74.0 12.10 0.60 14.92 541.0 74.0 12.00 0.54 14.83 538.0 73.0 11.70 0.49 14.76...
  • Page 43 4.10 0.13 12.11 473.0 74.0 3.90 0.12 12.02 471.0 74.0 3.80 0.13 11.96 470.0 74.0 3.60 0.13 11.91 467.0 75.0 3.40 0.15 11.85 469.0 75.0 3.30 0.14 11.97 469.0 75.0 3.10 0.13 12.07 469.0 74.0 2.90 0.13 12.09 468.0 74.0 2.70 0.13 11.87...
  • Page 44: Run 2

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 1 High Burn 10-minute data Proportional Rate Verification This data set is presented to verify that when proportional rates are calculated at the required 10- minute interval, required specification that only one reading can be outside of the 90% to 110% are maintained.
  • Page 45 OMNI-Test Laboratories, Inc. Wood Heater Test Data Proportional Rate Verification Run: Manufacturer: Travis Industries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.36 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 46: Run 3

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 2 Medium Burn OMNI-Test Laboratories, Inc. Page 46 of 186...
  • Page 47 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E2780 / ASTM E2515 Run: Manufacturer: Travis Industries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.38 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 48 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E2780 / ASTM E2515 Run: Manufacturer: Travis Industries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.38 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 49 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E2780 / ASTM E2515 Run: Manufacturer: Travis Industries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 17.38 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 50 OMNI-Test Laboratories, Inc. Wood Heater Lab Data - ASTM E2780 / ASTM E2515 Manufacturer: Travis Industries Equipment Numbers: Model: Endeavor Tracking No.: 2337 Project No.: 0028WS062E Run #: 2 Date: 1/8/19 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe...
  • Page 51 OMNI-Test Laboratories, Inc. Wood Heater Test Results - ASTM E2780 / ASTM E2515 Manufacturer: Travis Industries Model: Endeavor Project No.: 0028WS062E Tracking No.: 2337 Run: 2 Test Date: 01/08/19 Burn Rate 1.69 kg/hr dry Average Tunnel Temperature 106 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 17.38 feet/second...
  • Page 52 Wood Heater Efficiency Results - CSA B415.1 Manufacturer:Travis Industries Technician Signature: Endeavor Model: 01/08/19 Date: Run: Control #: 0028WS062E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 74.1% 80.1% Overall Efficiency 95.4% 95.4% Combustion Efficiency 84.0%...
  • Page 53 VERSION: 2.2 12/14/2009 Manufacturer: Travis Industries Appliance Type: Non-cat Model: Endeavor Date: 1/8/2019 Temp. Units (F or C) Run: 2 Weight Units (kg or lb) Control #: 0028WS062E Test Duration: 395 Output Category: III Fuel Data D. Fir Wood Moisture (% wet): 16.48...
  • Page 54 8.20 0.13 10.87 398.0 78.0 7.70 0.14 10.73 393.0 76.0 7.20 0.12 10.69 389.0 77.0 6.70 0.15 9.98 381.0 76.0 6.30 0.23 9.52 363.0 75.0 5.90 0.23 9.33 351.0 77.0 5.60 0.26 8.67 340.0 77.0 5.30 0.35 8.09 330.0 76.0 5.00 0.36 8.10...
  • Page 55 0.80 1.24 3.47 196.0 73.0 0.70 1.28 3.29 192.0 71.0 0.70 1.31 3.22 189.0 71.0 0.60 1.32 3.12 185.0 71.0 0.50 1.17 3.09 182.0 71.0 0.50 1.18 3.04 180.0 71.0 0.40 1.17 2.99 178.0 71.0 0.30 1.20 2.86 176.0 71.0 0.30 1.23 2.55...
  • Page 56 Page 56 of 186...
  • Page 57 Page 57 of 186...
  • Page 58: Run 4

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 3 High Burn 1-minute data Emissions Results (Cold to Hot Cycle) OMNI-Test Laboratories, Inc. Page 58 of 186...
  • Page 59 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.91 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 60 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.91 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 61 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.91 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 62 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.91 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 63 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.91 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 64 OMNI-Test Laboratories, Inc. Wood Heater Lab Data Manufacturer: Travis Indusstries Equipment Numbers: Model: Endeavor Tracking No.: 2337 Project No.: 0028WS062E Run #: 3 Date: 1/9/19 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe Weights or Dish # Final, mg Tare, mg Particulate, mg B.
  • Page 65 OMNI-Test Laboratories, Inc. Wood Heater Test Results Manufacturer: Travis Indusstries Model: Endeavor Project No.: 0028WS062E Tracking No.: 2337 Run: 3 Test Date: 01/09/19 Burn Rate 4.40 kg/hr dry Average Tunnel Temperature 137 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 19.91 feet/second...
  • Page 66 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method - May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators - 10 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 67 Page 67 of 186...
  • Page 68 Page 68 of 186...
  • Page 69: Run 5

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 3 High Burn 10-minute data Efficiency and Heat Output Results Kindling and start-up fuel removed from calculations OMNI-Test Laboratories, Inc. Page 69 of 186...
  • Page 70 OMNI-Test Laboratories, Inc. Wood Heater Test Data Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 71 OMNI-Test Laboratories, Inc. Wood Heater Test Data Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 72 OMNI-Test Laboratories, Inc. Wood Heater Test Data Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 73 OMNI-Test Laboratories, Inc. Wood Heater Test Data Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow: 219.5...
  • Page 74 Wood Heater Efficiency Results - CSA B415.1 Manufacturer: Travis Indusstries Technician Signature: Endeavor Model: 01/09/19 Date: Run: Control #: 0028WS062E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 73.4% 79.4% Overall Efficiency 98.3% 98.3%...
  • Page 75 VERSION: 2.2 12/14/2009 Manufacturer: Travis Indusstries Appliance Type: Non-cat Model: Endeavor Date: 1/9/2019 Temp. Units (F or C) Run: 3 Weight Units (kg or lb) Control #: 0028WS062E Test Duration: 102 Output Category: IV Fuel Data D. Fir Wood Moisture (% wet): 18.12...
  • Page 76 15.70 0.31 13.28 546.0 71.0 15.40 0.34 13.28 546.0 71.0 15.20 0.34 13.20 544.0 71.0 14.90 0.33 13.19 544.0 71.0 14.60 0.30 13.14 539.0 71.0 14.30 0.29 13.17 539.0 72.0 14.10 0.31 13.23 539.0 71.0 13.80 0.31 13.25 540.0 72.0 13.60 0.28 13.26...
  • Page 77 5.70 0.14 11.70 481.0 74.0 5.40 0.12 11.79 484.0 74.0 5.20 0.11 11.85 486.0 75.0 5.10 0.12 11.83 486.0 74.0 4.80 0.16 11.71 484.0 75.0 4.60 0.19 11.58 481.0 75.0 4.50 0.21 11.46 479.0 75.0 4.30 0.21 11.45 477.0 75.0 4.10 0.22 11.41...
  • Page 78: Run 6

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 4 Low Burn OMNI-Test Laboratories, Inc. Page 78 of 186...
  • Page 79 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions and Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.20 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 80 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions and Efficiency Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.20 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 81 OMNI-Test Laboratories, Inc. Wood Heater Lab Data Manufacturer: Travis Indusstries Equipment Numbers: Model: Endeavor Tracking No.: 2337 Project No.: 0028WS062E Run #: 4 Date: 1/9/19 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe Weights or Dish # Final, mg Tare, mg Particulate, mg B.
  • Page 82 OMNI-Test Laboratories, Inc. Wood Heater Test Results Manufacturer: Travis Indusstries Model: Endeavor Project No.: 0028WS062E Tracking No.: 2337 Run: 4 Test Date: 01/09/19 Burn Rate 1.11 kg/hr dry Average Tunnel Temperature 94 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 20.20 feet/second...
  • Page 83 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method - May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators - 12 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 84 Wood Heater Efficiency Results - CSA B415.1 Manufacturer:Travis Indusstries Technician Signature: Endeavor Model: 01/09/19 Date: Run: Control #: 0028WS062E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 74.0% 80.0% Overall Efficiency 92.8% 92.8% Combustion Efficiency 86.1%...
  • Page 85 VERSION: 2.2 12/14/2009 Manufacturer: Travis Indusstries Appliance Type: Non-cat Model: Endeavor Date: 1/9/2019 Temp. Units (F or C) Run: 4 Weight Units (kg or lb) Control #: 0028WS062E Test Duration: 590 Output Category: II Fuel Data D. Fir Wood Moisture (% wet): 17.31...
  • Page 86 5.20 1.60 5.94 213.0 81.0 5.00 1.75 5.56 201.0 80.0 4.80 1.63 6.01 192.0 78.0 4.60 1.69 5.94 186.0 78.0 4.40 1.85 5.75 181.0 79.0 4.30 2.03 5.17 178.0 78.0 4.10 2.14 4.56 173.0 78.0 3.90 2.11 4.48 168.0 77.0 3.80 2.14 4.05...
  • Page 87 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 5 High Burn 5-minute data Non-Sampling (Cold to Hot Cycle) OMNI-Test Laboratories, Inc. Page 87 of 186...
  • Page 88 OMNI-Test Laboratories, Inc. Wood Heater Test Data Run: Manufacturer: Travis Indusstries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole Initial Tunnel Flow:...
  • Page 89 OMNI-Test Laboratories, Inc. Wood Heater Test Results Manufacturer: Travis Indusstries Model: Endeavor Project No.: 0028WS062E Tracking No.: 2337 Run: 5 Test Date: 01/10/19 Burn Rate 5.13 kg/hr dry Average Tunnel Temperature #DIV/0! degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs...
  • Page 90 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method ‐ May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators ‐ 10 lb/ft  Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING Core 45‐65% of Total Load Weight, Remainder 35‐55% of Total Load Weight JURISDICTION AND THE PRESIDENT OF THE SOCIETY.
  • Page 91 Page 91 of 186...
  • Page 92 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Run 6 Medium Burn OMNI-Test Laboratories, Inc. Page 92 of 186...
  • Page 93 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions and Efficiency Data Run: Manufacturer: Travis Industries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.09 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 94 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions and Efficiency Data Run: Manufacturer: Travis Industries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.09 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 95 OMNI-Test Laboratories, Inc. Wood Heater Test Data Emissions and Efficiency Data Run: Manufacturer: Travis Industries PM Control Modules: 371, 372 Model: Endeavor Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.09 ft/sec. Tracking No.: 2337 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 96 OMNI-Test Laboratories, Inc. Wood Heater Lab Data Manufacturer: Travis Industries Equipment Numbers: Model: Endeavor Tracking No.: 2337 Project No.: 0028WS062E Run #: 6 Date: 1/10/19 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe Weights or Dish # Final, mg Tare, mg Particulate, mg B.
  • Page 97 OMNI-Test Laboratories, Inc. Wood Heater Test Results Manufacturer: Travis Industries Model: Endeavor Project No.: 0028WS062E Tracking No.: 2337 Run: 6 Test Date: 01/10/19 Burn Rate 1.83 kg/hr dry Average Tunnel Temperature 111 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 20.09 feet/second...
  • Page 98 Wood Heater Efficiency Results - CSA B415.1 Manufacturer: Travis Industries Technician Signature: Endeavor Model: 01/10/19 Date: Run: Control #: 0028WS062E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 74.7% 80.8% Overall Efficiency 96.0% 96.0%...
  • Page 99 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method - May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators - 12 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 100 VERSION: 2.2 12/14/2009 Manufacturer: Travis Industries Appliance Type: Non-cat Model: Endeavor Date: 1/10/2019 Temp. Units (F or C) Run: 6 Weight Units (kg or lb) Control #: 0028WS062E Test Duration: 355 Output Category: III Fuel Data D. Fir Wood Moisture (% wet): 17.37...
  • Page 101 8.80 0.14 12.21 413.0 81.0 8.20 0.12 11.12 403.0 81.0 7.60 0.09 11.17 393.0 80.0 7.20 0.12 10.48 386.0 80.0 6.80 0.26 10.27 382.0 80.0 6.40 0.30 9.98 367.0 81.0 6.00 0.27 9.49 355.0 80.0 5.60 0.40 9.32 346.0 81.0 5.20 0.63 8.43...
  • Page 102 0.50 0.89 4.91 219.0 77.0 0.40 0.93 4.90 217.0 78.0 0.30 1.02 4.74 216.0 78.0 0.20 1.07 4.61 215.0 78.0 0.10 1.02 4.45 214.0 78.0 0.00 1.09 4.38 212.0 77.0 Page 102 of 186...
  • Page 103 Page 103 of 186...
  • Page 104 Page 104 of 186...
  • Page 105: Quality Assurance/Quality Control

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Section 4 Quality Assurance/Quality Control OMNI-Test Laboratories, Inc. Page 105 of 186...
  • Page 106 This report is issued within the scope of OMNI’s accreditation. Accreditation certificates are available upon request. The manufacturing facilities and quality control system for the production of the Endeavor at Travis Industries, Inc. were evaluated to determine if sufficient to maintain conformance with OMNI’s requirements for product certification.
  • Page 107: Sample Analysis

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Sample Analysis Analysis Worksheets Tared Filter, Probe, and O-Ring Data OMNI-Test Laboratories, Inc. Page 107 of 186...
  • Page 108 Page 108 of 186...
  • Page 109 Page 109 of 186...
  • Page 110 Page 110 of 186...
  • Page 111 Page 111 of 186...
  • Page 112 Page 112 of 186...
  • Page 113 Page 113 of 186...
  • Page 114 Page 114 of 186...
  • Page 115 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E 0028WS062E Page 115 of 186...
  • Page 116 Page 116 of 186...
  • Page 117 Page 117 of 186...
  • Page 118 Page 118 of 186...
  • Page 119 Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Calibrations Methods EPA 28R, ASTM E2515, ASTM E3053 ID # Lab Name/Purpose Log Name Attachment Type 10 lb Weight Weight Standard, 10 lb. Calibration Certificate 110850562 Platform Scale Weigh-Tronix E1010 Calibration Certificate Digital Barometer...
  • Page 120 Page 120 of 186...
  • Page 121 Page 121 of 186...
  • Page 122 Page 122 of 186...
  • Page 123 Page 123 of 186...
  • Page 124 Page 124 of 186...
  • Page 125 OMNI-Test Laboratories, Inc. Thermal Metering System Calibration Y Factor Previous Calibration Comparision Acceptable Manufacturer: Apex Date 1/16/2018 Deviation (5%) Deviation Model: XC-60-EP y Factor 0.997 0.04985 0.014 Acceptable Serial Number: 0702003 Acceptance OMNI Tracking No.: OMNI-00371 Calibrated Orifice: FALSE Current Calibration Average Acceptable y Deviation 0.020...
  • Page 126 OMNI-Test Laboratories, Inc. DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET Instrument to be calibrated: Pressure Transducer______________ Maximum Range: 0-2” WC ID Number: OMNI-00371 Calibration Instrument: Digital Manometer ID Number: OMNI-00395 Date: 7/16/18 B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC. Range of Digital Pressure Gauge...
  • Page 127 7/20/18 Page 127 of 186...
  • Page 128 OMNI-Test Laboratories, Inc. Thermal Metering System Calibration Y Factor Previous Calibration Comparision Acceptable Manufacturer: Apex Date 1/17/2018 Deviation (5%) Deviation Model: XC-60-EP y Factor 0.981 0.04905 0.007 Acceptable Serial Number: 0702004 Acceptance OMNI Tracking No.: OMNI-00372 Calibrated Orifice: FALSE Current Calibration Average Acceptable y Deviation 0.020...
  • Page 129 OMNI-Test Laboratories, Inc. DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET Instrument to be calibrated: Pressure Transducer______________ Maximum Range: 0-2” WC ID Number: OMNI-00372 Calibration Instrument: Digital Manometer ID Number: OMNI-00395 Date: 7/16/18 B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC. Range of Digital Pressure Gauge...
  • Page 130 7/20/18 Page 130 of 186...
  • Page 131 Page 131 of 186...
  • Page 132 Calibration Record Vaneometer Air Velocity Meter OMNI-00559 Calibration Service Record Date Results Date of next Calibration 7/12/2018 B. Davis Installed a new Vane as per 1/12/2019 manufacturer’s instructions. Page 132 of 186...
  • Page 133 Page 133 of 186...
  • Page 134 Z R E Z R E NDIR/0 NDIR/0 Z R E Z R E Z R E Z R E Z R E Z R E Z R E Z R E Z R E Z R E NDIR/0 NDIR/0 NDIR/0 NDIR/0 NDIR/0...
  • Page 135 JJ Calibrations, Inc. Certificate of Calibration 7007 SE Lake Rd Portland, OR 97267-2105 Certificate Number: 692254 Phone 503.786.3005 FAX 503.786.2994 Omni-Test Laboratories O n S i t e 13327 NE Airport Way 181203 Portland, OR 97230 0723.01 Order Date: 01/11/2019 Calibration Authorized By: Property #:...
  • Page 136 Page 136 of 186...
  • Page 137: Example Calculations

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Example Calculations OMNI-Test Laboratories, Inc. Page 137 of 186...
  • Page 138 Equations and Sample Calculations Manufacturer: Travis Indusstries Model: Endeavor Run: Category: Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
  • Page 139 OMNI-Test Laboratories, Inc. BR – dry burn rate, kg/hr ASTM E2780 equation (5) 60 M FTAdb θ Where, = Total length of test run, min θ Sample Calculation: = 10.92 = 590 θ 60 x 10.9 kg/hr 1.11 Control No. P-SSAR-0003 Run 4 emissions Page 139 of 186...
  • Page 140 OMNI-Test Laboratories, Inc. – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equations (9)        Where: strav Adjustment factor for center of tunnel pitot tube placement, Fp = , ASTM E2515 Equation (1) scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent...
  • Page 141 OMNI-Test Laboratories, Inc. – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3)        3600 Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in dilution tunnel, = P...
  • Page 142 OMNI-Test Laboratories, Inc. – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6) Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
  • Page 143 OMNI-Test Laboratories, Inc. – Total Particulate Matter Collected, mg ASTM E2515 Equation (12)    Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train 1 (first hour): Using equation for Train 1 (post-first hour): -0.9...
  • Page 144 OMNI-Test Laboratories, Inc. - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dsc ASTM E2515 equation (13)   Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train 1:...
  • Page 145 OMNI-Test Laboratories, Inc. – Total Particulate Emissions, g ASTM E2515 equation (15)        Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr Total time of test run, minutes θ...
  • Page 146 OMNI-Test Laboratories, Inc. PR - Proportional Rate Variation ASTM E2515 equation (16)                   Where: θ = Total sampling time, min θ = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith”...
  • Page 147 OMNI-Test Laboratories, Inc. – Particulate emissions for test run, g/hr ASTM E2780 equation (6) = 60 (E /θ) Where, = Total particulate emissions, grams θ = Total length of full integrated test run, min Sample Calculation: (Dual train average) = 10.90 g θ...
  • Page 148 OMNI-Test Laboratories, Inc. – Particulate emission factor for test run, g/dry kg of fuel burned ASTM E2780 equation (7) FTAdb Sample Calculation: (Dual train average) = 10.90 g 10.92 kg 10.90 / ### 10.92 g/kg 1.00 Control No. P-SSAR-0003 Run 4 emissions Page 148 of 186...
  • Page 149: Labeling & Owner's Manual

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Section 5 Labeling & Owner’s Manual OMNI-Test Laboratories, Inc. Page 149 of 186...
  • Page 150 Manufactured by: Do not route power cord under or in front of appliance. U.S. ENVIRONMENTAL PROTECTION AGENCY TRAVIS INDUSTRIES, INC. Replace glass only with 5mm neoceramic or Certified to comply with 2020 particulate emission standards using cord wood. 12521 Harbour Reach Drive ceramic glass.
  • Page 151 Endeavor II Wood Stove Owner's Manual  Freestanding Stove  Mobile-Home Approved  Alcove Approved  Hearth-Stove Approved Save these instructions for future reference SAFETY NOTICE: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
  • Page 152: Introduction

    Introduction Introduction We welcome you as a new owner of a Lopi Endeavor II wood-burning stove. In purchasing a Lopi Endeavor II you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Lopi Endeavor II is one of the finest appliances the world over.
  • Page 153: Safety Precautions

    Using Outside Air with the PedestalError! Bookmark not defined.   Starting a Fire ..........20   Outside Air Boot Installation (Part number Adjusting the Burn Rate ........ 21   99200134) ............35   Approximate Air Control Settings ......21   © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 154 This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 155 Avoid placing wood against the glass when loading. Do not slam the door or strike the glass. Do not throw this manual away. Travis Industries, Inc. grants This manual has important no warranty, implied or This operating and maintenance...
  • Page 156: Installation Options

    This heater meets the 2020 U.S. EPA’s cord wood emission limits for wood heaters. Tested to EPA Alt-125, ASTM E3053-17, ASTM 2515-11, CSA B415.1-10 this heater has been shown to deliver heat at rates ranging from 15,435 to 67,090 BTU/hr and an emission value of 1.40g/h. Report No. 0028WS062E © Travis Industries 2/25/2019 - 1507 Endeavor II...
  • Page 157: Packing List

    Bypass tool Planning the Installation We suggest that you have an authorized Travis Industries dealer install your stove. If you install the stove yourself, your authorized dealer should review your installation plans. Check with local building officials for any permits required for installation of this stove and notify your insurance company before proceeding with installation.
  • Page 158: Floor Protection Requirements

    (for qualified installers only) Floor Protection Requirements  Stove must be placed on the Travis Industries legs or pedestal.  Floor protection must extend to the sides, rear, and front of the stove (see “Clearances” below for minimum floor protection).
  • Page 159: Top View - Straight Installation

    24” 610mm NOTE: Vent diameter varies depending on 5-3/4” 146mm brand and model. Measure front 23-1/2” clearances from the face 597mm of the stove (unibody). Figure 3 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 160: Chimney Connector Requirements

    Offsets must be used to maintain the stove to wall clearance. Mobile homes must use the clearances listed in this manual under "Additional Requirements for Mobile Home Installations". © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 161: Chimney Requirements

    `plugging' of the chimney. Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates excessive draft. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 162: Chimney Termination Requirements

    Outside air entrance must be placed so it does not become blocked by snow . Outside Air Connector Air may be drawn from a ventilated IDB01279 crawl space or use an air duct. Figure 6 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 163: Alcove Installation Requirements

    Minimum height of alcove 84” (2134mm) Non-combustible alcove construction (on walls and ceiling) - see the explanation above. Ventilated air space Min. 3 1/2" (89mm) non- combustible material 1" (25mm) Min. Non-combustible reinforcer Figure 7 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 164: Mobile Home Requirements

    The appliance must be grounded to the chassis of the mobile home (consult your building official).  WARNING: DO NOT INSTALL IN SLEEPING ROOM.  CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE Figure 9 MAINTAINED. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 165: Standard Ceiling With A Factory Built Chimney

    Minimum 15' Chimney Maximum 33' Connector Sections Floor Protection Stove Clearances (See the section "Floor (See the section "Stove Protection Requirements" Placement Requirements" for more details) for more details) Figure 11 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 166: Exterior Factory Built Chimney

    Remove damper or wire it open Floor Protection (See the section "Floor Protection Requirements" See the section for more details) "Stove Placement Requirements" for minimum clearances required. Figure 13 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 167: Hearth Stove Direct Connection

    (U.L. Listed) (U.L. Listed) wall wall thimble. Chimney connector sections thimble. See the section Make sure the "Floor Protection clean-out seals in Requirements" place. Figure 15 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 168: Safety Notice

    Over-firing may lead to damage of plated surfaces. If you are uncertain of over-firing conditions, we suggest placing a stove thermometer (e.g. Rutland® Model 710) directly over the door on the stove top - temperatures exceeding 800° are generally considered over-firing and will void the warranty. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 169: Opening The Door

    During normal operation, push the bypass in. Bypass Pulled Out Used for starting and re-loading Use the included pull tool to operate the bypass rod Bypass Pushed In Used for normal operation © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 170: Starting A Fire

    This should start the chimney drafting (this eliminates "cold air blockage"). Use plenty of kindling to ensure the stove reaches a proper temperature. Once the kindling is burning rapidly, place a few larger pieces of wood onto the fire. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 171: Adjusting The Burn Rate

    The air control becomes hot during operation - use gloves or a tool to prevent burns. The air control may take several minutes to influence the burn rate. When making adjustments, you may wish to let the stove burn for 10 minutes to gauge performance. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 172: Understanding Your Heater's Combustion System

    © Travis Industries 2/1/2019 - 1507...
  • Page 173: Optional Blower Operation

    The blower will make a slight "humm" as it pushes air through the stove. Hint: Make sure the leveling bolts on legs are extended - preventing the hearth from amplifying any vibrations. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 174: Hints For Burning

    Cut wood to length and Store the wood off the ground in a chop into quarters. covered area. Allow for airflow Air Flow around the wood to dry the wood. Air Flow Air Flow © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 175: Do Not Burn List

    Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 176: Troubleshooting

    28 for details.  Check the ash bed for coals. Often, coals are still glowing under a slight bed of fly ash. By raking these into a pile you can re-start your stove quickly. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 177: Daily Maintenance (While Stove Is In Use)

    The ash acts as a light abrasive. The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 178: Monthly Maintenance (While Appliance Is In Use)

    If you are not certain of creosote inspection, contact your dealer or local chimney sweep for a full inspection. Excess creosote buildup may cause a chimney fire that may result in property damage, injury, or death. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 179: Yearly Maintenance

    Slight scaling or rusting of the metal is normal. Make sure the push pins hold the air tubes in place. Floor and Wall Firebricks - replace any severely damaged firebrick along the side or floor of the firebox. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 180: Door Parts

    You may need to open and close the door repeatedly to get the gasket to seat fully. Replacing the Door Handle See the illustration above for a component list (see pg. 28 for details on adjusting the door). © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 181: Firebox Parts

    Do not pry firebrick - they chip and crack easily. Remove the floor firebricks first. The side firebricks are removed later because they are pinned in place by the floor firebrick. Clean the firebox prior to replacing the firebrick. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 182: Baffle Removal & Replacement

    Air Tube Removal & Replacement Air Tube Collar Air Tube Remove the left pin on the air tube collar Roll Pin Slide the air tube to the left, swing it down and remove from the firebox. © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 183 16. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect. 17. This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.
  • Page 184: Listing Label

    Optional Equipment Listing Label © Travis Industries 2/25/2019 - 1507 Endeavor II...
  • Page 185: Outside Air Boot Installation (Part Number 99200134)

    Floor (and hearth) gasket to seal. Air Tube Removal & Replacement ....32 Adjusting the Burn Rate ........21 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 186 Heating Specifications ........6 Why Dry Wood is Key ........24 Hints for Burning ..........24 Wood Cutting and Storage ......24 Important Information ......... 2 Yearly Maintenance ......... 29 Installation Options ..........6 © Travis Industries 2/1/2019 - 1507 Endeavor II...
  • Page 187: Appendix A Alt-125 E3053 Letter

    Travis Industries, Inc. Model: Endeavor Report Number:0028WS062E Appendix A Alt-125 E3053 Letter OMNI-Test Laboratories, Inc.
  • Page 188 227 of 229...
  • Page 189 228 of 229...
  • Page 190 229 of 229...

Table of Contents