If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com. V01.00 | 2023/01 | 4 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
The scope of delivery includes: IP65/IP67 power supply Quick Start Guide Turck service Turck supports you with your projects, from initial analysis to the commissioning of your applic- ation. The Turck product database under www.turck.com contains software tools for program- ming, configuration or commissioning, data sheets and CAD files in numerous export formats.
The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
Operator interface (LEDs and buttons) Functional principle The device converts an AC input voltage of 320…550 VAC into a 24 VDC output voltage. V01.00 | 2023/01 | 8 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
If an external fuse is used, type B or C circuit breakers of at least 6 A have to be used to prevent unwanted tripping of the circuit breaker. V01.00 | 2023/01 | 9 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
Page 10
Such use is not included in the approval according to UL 61010 and IEC 62368. PSU67 open Fig. 4: 2-phase operation /VAC Fig. 5: Performance in 2-phase operation V01.00 | 2023/01 | 10 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
Fig. 6: Hold-up time vs. input voltage L1 L2 L3 Input Voltage -5 % Output Voltage Hold-up Time Fig. 7: Shutdown behavior V01.00 | 2023/01 | 11 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
90 % × V < > 1 ms 1 ms 250 ms open closed open closed Fig. 8: Relay-OK contact - contact behavior V01.00 | 2023/01 | 12 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
TN, TT, IT delta mains systems or IT star mains systems without insulation monitoring: Use in zones of overvoltage category II up to 2000 m (6560 ft) V01.00 | 2023/01 | 13 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
Commissioning Commissioning After connecting the wires and by switching on the AC input voltage, the device automatically goes into operation. V01.00 | 2023/01 | 15 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
All LEDs flash for 5 s to indicate that the key lock status has changed. The display returns to normal operation. V01.00 | 2023/01 | 16 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
The device has switched off due to overtemperature. As soon as the tem- perature reaches the normal operating range, the output switches on again and the STATUS LED lights up permanently green. V01.00 | 2023/01 | 17 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
Observe our return acceptance conditions when returning the device to Turck. 11.1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed. The decontamination declaration can be downloaded from https://www.turck.de/en/retoure-service-6079.php and must be completely filled in, and affixed securely and weather-proof to the outside of the packaging.
3 AC, 480 V typ. 0.95, at 500 W AC Input Range /VAC Fig. 12: Voltage range – input voltage AC V01.00 | 2023/01 | 19 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
Page 20
0.90 0.85 3 × 480 Vac 0.80 0.75 0.70 Fig. 15: Power factor vs. output power (at 24 VDC output voltage) V01.00 | 2023/01 | 20 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
1 mA at 5 VDC Isolation voltage Duration Type test 60 s 2830 VAC 500 VAC Routine test 2550 VAC 500 VAC V01.00 | 2023/01 | 23 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
S. fig.: Output power vs. ambi- ent temperature [} 21] Altitude Max. 5000 m (16 400 ft) S. fig.: Output power vs. alti- tude [} 21] V01.00 | 2023/01 | 24 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
Page 25
Max. 32.5 VDC redundant circuit limits the maximum output voltage. The output shuts down and auto- matically attempts to restart. V01.00 | 2023/01 | 25 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
Page 26
350 W at max. 60 °C - 25 + 45 + 55 + 70 T/°C Fig. 22: Derating – standard mounting orientation V01.00 | 2023/01 | 26 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...