REMOVAL OF FRONT GRILLE

Remove the front intake grille.
1
Pull up the front intake
grille about 90° and slide
it slightly to the left to
unhook the tabs.
Remove the front grille.
3
a
Remove the adhesive tape from all sides of the front grille.
At bottom right side of the front grille, press inward on cabinet near the power cord, and pull
b
the grille outward to the right until right tab releases.
c
At the bottom left side, push inward on cabinet and pull the grille outward to the left to release
the left tab.
Do not pull the bottom edge toward you more than 3 inches to prevent the two top tabs from
damage.
d
Slide the front grille upwards to free the two top tabs from slots at the top of the cabinet.

HOW TO ATTACH THE DRAIN PAN (OPTIONAL)

Condensed water drainage
This air conditioner employs a "Slinger-Up System" which is designed to splash the condensed
water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound.
If the splashing sound annoys you, you can provide an outside drainage by using the following
procedure which may, however, cause a small loss of performance.
Note: The cabinet should be installed tilted slightly lower to the rear for necessary condensate
drainage. (Max. 13/32")
Remove the rubber plug and slide the chassis out from
1
the cabinet.
Install the optional drain pan (part no. CWH40175).
2
Install the drain pan at the right
corner of the cabinet using 2
screws (part no. CWG86C733).
Note
The
drain
CWH40175) can be obtained
from nearest servicenter.

MAIN UNIT

3
4
5
8 Ventilation lever
The ventilation lever must be in the CLOSE position in order
to maintain the best cooling conditions. When fresh air is
necessary in the room, set the ventilation lever to the OPEN
position. The damper is opened and room air is drawn out.
TYPES OF SIGNAL SOUND
One long "Beep" and one short "Beep". (Sound from the main unit.)
Remove the
rubber plug
INTERNAL VIEW
Screws
pan
(part
no.
Drain pan (optional)
1 Air inlet louver
1
2
2 Cabinet
6
3 Power cord
7
7 Vertical airflow direction vane
8
9
3
Remove the air filter.
2
Tilt up and pull
out the air filter
by the holder.
Connect a drain hose (optional).
3
Fit the drain hose to the drain pan.
Note
Drain hose or tubing can be
purchased locally to satisfy your
particular needs.
Slide the chassis back into the
4
cabinet.
Reinstall the cabinet screws.
Secure the cabinet to chassis by
using screws.
4 Air filter
5 Front intake
grille
6 Front grille
(Airflow direction adjustment up-down).
The vertical airflow direction
vane is controlled by
rotating the horizontal vane
forward or backward.
Air filter
d
a
c
b
Maximum
13/32"
Condensed water
EXTERNAL VIEW
Drain hose
(not included)
Under-side view with drain
pan and hose in place.
9 Touch control panel
e
d
TIMER
°F
a
TEMP/TIMER
SET
hr
SET/
f
CANCEL
COOL
b
MODE
AIR SWING
FAN
h
HIGH
Wireless
c
MED
FAN SPEED
R e m o t e C o n t r o l
LOW
a Display Panel
b MODE selection pad
c FAN SPEED selection pad
d TEMPERATURE/TIMER
setting pad
e TIMER pad
f Timer SET/CANCEL pad
g OPERATION OFF/ON pad
h AIR SWING pad
i ECONOMY pad
OPERATION
OFF/ON
g
ECONOMY
i

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cw-xc123vu

Table of Contents