Installation Preparations

Before the installation, ensure that:
The charger power is within the allowed load range of the residence.
Cables and RCBOs meet the installation and usage requirements.
If the AC input power cable exposed to the outdoor environment is 3 m or longer, consult the local installer. You are advised
to install a surge protective device (SPD) at the upstream of the charger's RCBO. The SPD specifications should meet the
following requirements: Uc = 385 V AC, In ≥ 10 kA, and Up ≤ 2 kV. The cable between the SPD and charger must be at
least 3 m.
A network cable that is long enough is prepared if the charger is connected to a wired network.
The installation area should be covered by a wireless network if the charger is connected to the network through WiFi.
If the PV power preferred mode and dynamic charging power mode are used, you need to configure an electricity meter. Scan the
QR code in "About This Manual" and see detailed information about the meter in "Meter Description."
Preparing Tools
Personal protective
equipment
Hardware installation
tools
Cable installation tools
Measurement instruments
Auxiliary materials
Preparing Cables
Cable Type
AC input power cable (single-phase three-wire)
AC input power cable (three-phase five-wire)
Note: To facilitate cabling, aluminum wires and solid copper wires are not recommended.
Preparing an RCBO
Input
Specifications
Single-phase /
2P/4P RCBO, 40 A (50 A is recommended if the ambient temperature is higher than 45°C), Type A
or B, in compliance with local regulations.
Three-phase
Safety helmet
Phillips insulated torque
screwdriver (M4/M5/M6)
Marker
Wire stripper
Clamp meter
Insulation tape
Protective gloves
Insulated security torx
torque screwdriver (TT20)
Rubber mallet
Crimping tool
Steel measuring tape
Heat-shrink tubing
Operating Current
32 A
7
Insulated shoes
Hammer drill and
drill bit (Φ10)
Scissors
Level instrument
Cord end terminal
Cross-sectional Area
6~10 mm
2
6~10 mm
2