Standard Pulse Formats
The control panel can use the Ademco slow, Silent Knight fast and Sescoa standard pulse reporting formats (see Table 7).
Ademco Express
The Ademco Express is a high-speed reporting format that communicates 2-digit (00 to FF) report codes. The Ademco Express does not use the Contact ID Report
Codes.
Ademco Contact ID
Ademco Contact ID is a fast communicator format that uses tone reporting. To program the report codes, use the 2-digit hexadecimal values from the Contact ID
Report Codes List in the "EVOHD+ Programming Guide". Enter 00 to disable reporting or FF to use the default report code from the Automatic Report Code List in the
"EVOHD+ Programming Guide". To program a set of default Contact ID codes, refer to section on page 48.
SIA FSK
SIA FSK is a fast communicator format that uses tone reporting. To program the report codes, enter 00 to disable reporting or any other value to use the default
report code from the Automatic Report Code List in the "EVOHD+ Programming Guide". To program a set of default SIA FSK codes, refer to Auto Report Code
Programming on page 48.

Event Call Direction

Event groups can be programmed to dial up to four monitoring station telephone numbers with one used as a backup. The numbers are dialed sequentially,
skipping any disabled numbers and stopping once all selected telephone numbers have been reached. If the control panel still fails to report to a monitoring station
telephone number after reaching the Maximum Dialing Attempts (see section on page 46), the control panel will dial the selected backup telephone number. For
each section enable or disable the options:
Troubles and Restore Troubles: [3080]
Special System, Arming, Disarming and Alarm Reporting: [3081]
Access Code and Keyswitch Arming and Disarming
Partition 1: [3127]
Partition 3: [3327]
Partition 2: [3227]
Partition 4: [3427]
Zone Alarms and Alarm Restores
Partition 1: [3128]
Partition 3: [3328]
Partition 2: [3228]
Partition 4: [3428]
Tampers and Tamper Restores
Partition 1: [3129]
Partition 3: [3329]
Partition 2: [3229]
Partition 4: [3429]
(default = only option [1] enabled)
Option Call:
[1]
Telephone Number 1
[2]
Telephone Number 2
[3]
Telephone Number 3
[4]
Telephone Number 4
Maximum Dialing Attempts*
S
[3056]
ECTION
(default = 008) The number (001 to 255, 000 = 8 attempts) programmed into section [3056] determines how many tries before proceeding to the next number. Also
refer to section .
* UL Note: For UL Listed systems, the maximum dialing attempts must be set to 5 to 10 attempts between the EVOHD+'s two telephone lines.
Delay Between Dialing Attempts
S
[3054]
ECTION
(default = 020) This delay can be set from 001 to 127 seconds.
Alternate Dialing Option
S
[3037]: O
[6]
ECTION
PTION
(default = disabled) When enabled, the control panel dials the selected backup telephone number after every failed attempt to contact a monitoring station
telephone number. When disabled, the control panel dials the backup telephone number after the Maximum Dialing Attempts (see section ) to one monitoring
station telephone number fail.
46
Partition 5: [3527]
Partition 7: [3727]
Partition 6: [3627]
Partition 8: [3827]
Partition 5: [3528]
Partition 7: [3728]
Partition 6: [3628]
Partition 8: [3828]
Partition 5: [3529]
Partition 7: [3729]
Partition 6: [3629]
Partition 8: [3829]
Option Call (select one only):
[5]
Backup on Number 1
[6]
Backup on Number 2
[7]
Backup on Number 3
[8]
Backup on Number 4
EVOHD+ Installation Guide