This section describes how to install the ZoneLogix™ PRO and UniDrive
configuration.
Zone Controller Installation
2.1
Mount the Zone Controller in a location where the motor cable reaches the connection header without putting strain
on the cable connector or the header. The Zone Controller can mount to the conveyor frame using two ¼ inch (0.25
in or 6.35 mm) bolts.
CAUTION: If mounting the control on a curved section of conveyor, use washers between the mounting plate and the conveyor
frame. This is to assure that the mounting plate is not distorted, causing damage to the enclosed printed circuit board assembly.
CAUTION: Removal of the cover will void the warranty. The cover does not make the controller waterproof or dustproof.
1. Zone Controller Installation
2. Motor Installation
3. DIP Switch Settings
4. Cable Connections
5. System Configuration
6. Diagnostics & Troubleshooting
Figure 3: Zone Controller Mounting Tabs
ZoneLogix™ PRO Zone Controller User Guide | Revision 1.0 November 2019 | Page 10