RT510WBC
Quick Guide
Introduction
The RT510TX thermostat will switch your heating system on or off, as needed, in accordance
with the time and temperature set by you. It can be used with the RXWBC605 integral plug-
in RF boiler control. The RF boiler control is a direct replacement for the basic time clock or
blanking plate usually supplied with the boiler. Installing the RF boiler control takes minutes.
Once installed, you will benefit from all the control features of the RT510TX thermostat.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
Box content
Desk Stand
RT510TX
RXWBC605
2 x AA Alkaline
Quick Guide
2 x Fixing Screws
Batteries
RXWBC605 Installation
Switch off the boiler at its main supply. Remove the outer casing and front fascia to
1
allow access to the main control panel.
A
Remove cover panel A upwards to remove.
2
B
Pull top tab B upwards, then outwards to
3
remove blanking plate or existing control.
First plug in the connector block C
4
ensuring correct orientation. Remember
to ensure the block is fully connected.
C
A
5
Now locate the boiler control's four hooks
then press in and down. Replace Cover
panel A.
Replace the front fascia and boiler's
6
outer casing.
Before switching the boiler on at its mains supply, ensure the module switch is in the
7
OFF position Ø.
i
Boiler may fire up on pre-heat mode on first turn on. If it does, it is advisable to
temporarily turn off your pre-heat until installtion is complete.
8
To ensure the boiler control is connected properly, please now move the switch to
MANUAL ON
. The boiler should now Fire and the LED on the your boiler
control should illuminate.
9
Now move the switch back to AUTO
.
RXWBC605 User Controls
A – LED This LED will be on when the thermostat is
demanding heat.
B – Mode Switch:
MANUAL ON / AUTO / OFF
C – SYNC Button - This is used only for pairing the RF
communications.
A
B
C
RXWBC605 Switch Position
When the switch on the Boiler Module is in
the AUTO position, the boiler control will
automatically receive the RF signal from the
thermostat and control the module output so
that it switches the boiler accordingly.
The user can also move the switch to the
MANUAL ON position; when in this mode, the
boiler will be always turned on and the LED
indicator will also be lit constantly.
The user can also move the switch to the OFF
position; when in this mode, the boiler will not
receive a signal from the RF thermostat.
RT510TX Button Functions
Key
Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
+Hr
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
SELECT
Press to confirm your settings
SET
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
+
+
Press the buttons for 3 seconds to enter Installer Mode
SELECT
Press the buttons for 3 seconds to enter Clock Settings
+
SET
RT510TX Dip Switch Settings
The DIP Switches can be found on the rear of your thermostat.
Control feature
TPI
Span
Operation
When TPI is selected on DIP
When Span is selected
switch № 2, the DIP switch
on DIP switch № 2,
№ 1 is functional. You can
the DIP switch № 1 is
choose the Cycles Per Hour
not functional.
between a lower comfort
temperature accuracy of
level (6CPH) and a higher
your thermostat is set to
comfort level (9CPH).
± 0.25 °C.
Test the Pairing Process
i
During test pairing, boiler control should flash confirming pair. If not, please follow
Pairing Process.
+Hr
+Hr
TEST / PAIRING
SELECT
SET
i
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
The LED will start flashing red.
Pairing Process
1
Ensure the switch on the RF
2
Gently press and hold the SYNC
integral boiler module is in the
button with a blunt object. After 3
AUTO position.
seconds the Boiler Control LED will
flash once every second to indicate it
is ready to pair and ready to receive
a signal from the thermostat.
Begin the pairing process
3
+Hr
+Hr
3 Sec
TEST / PAIRING
SELECT
SET
4
End the pairing process
+Hr
+Hr
3 Sec
TEST / PAIRING
SELECT
SET
i
Once the LED stops flashing, press the
Once paired please close the
The
TEST / PAIRING button for 3 sec.
boiler control panel.
SELECT
SET
TEST / PAIRING
SYNC Button
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET