The picture on the left shows the alarm report of the device without clearing after the alarm is generated, and the
picture on the right shows the report of the device alarm after manual clearing.

4.8.3 Alarm source configuration

DI alarm source:
The alarm mode can be configured through the register. The normal mode supports the configuration of the
disconnection alarm and the closing alarm. The device cannot use the disconnection alarm when the device is in
low power mode. The closed alarm supports low-power wake-up.
Battery Alarm Voltage Configuration:
The configurable range (0x00-0x0F) increases by 0.05V, the minimum configuration is 3.45V (0x00), and the
maximum configuration is 4.20V (ie 0x0F);
Copyright ©2012–2021, Chengdu Ebyte Electronic Technology Co., Ltd.
E90-DTU(400SL30L)_UserManual_EN
23