2.2.3 Simple use

Wiring: The computer is connected to the RS485 interface of ME31-XXXA0006 through USB to RS485, A is
connected to A, and B is connected to B.
Networking: Insert the network cable into the RJ45 port and connect to the PC.
Power supply: Use DC-12V switching power supply (DC 8~28V) to power ME31-XXXA0006.

2.3 Parameter Configuration

Step 1: Modify the IP address of the computer to be consistent with the device. Here I am modifying it to
192.168.3.100 to ensure that it is on the same network segment as the device and that the IP is different. If you
cannot connect to the device after the above steps, please turn off the firewall and try again;
Step 2: Open the network assistant, select the TCP client, enter the remote host IP192.168.3.7 (default parameter),
enter the port number 502 (default parameter), and select HEX to send.
Copyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.
Network port
ME31-XXXA0006_UserManual_EN
7