PA-28-181, ARCHER III
SECTION 4 - NORMAL PROCEDURES
To turn on the ADF-650D System:
•
Depress the PWR button momentarily and release.
If the PWR button is pressed for longer than 3 sec-
onds, the receiver will immediately shut off.
•
After successful self test, input desired station frequency and select ANT
mode.
•
Positively identify selected station or beacon.
•
Adjust volume control as required.
•
If ADF-650D System is used for navigation, select ADF or BFO mode
immediately after the station has been positively identified.
To turn off the ADF-650D System:
•
Depress the PWR button for at least 3 seconds.
If the PWR button is released within 3 seconds,
normal operations will resume.
ISSUED: JULY 12, 1995
REVISED: SEPTEMBER 12, 2005
NOTE
NOTE
SECTION 9
SUPPLEMENT 22
REPORT: VB-1611
3 of 10,
9-145