11.3.4. Connect The Cable To The Indoor Unit
1. The indoor and outdoor connecting cable can be connected without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5 mm
cord, type designation 245 IEC 57 or heavier cord.
• Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
• Earth lead wire shall be longer than the other lead wires as shown in the figure for the electrical safety in case of the slipping
out of the cord from the anchorage.
• Secure the cable onto the control board with the holder (clamper).
Terminal screw
Tightening torque N
M3
M4
M5
11.3.4.1. Wire Stripping and Connecting Requirement
cm {kgf
cm)
l
l
69~98 {7~10}
157~196 {16~20}
196~245 {20~25}